Do you have any question about this error?
Message type: E = Error
Message class: RSENQ - Lock Manager
Message number: 051
Message text: The roll up for InfoCube &1 has terminated
The roll-up for InfoCube &V1& has terminated.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Remove the cause of the termination. For reasons of consistency, you
are able to proceed only after the roll-up has been completed
successfully.
Error message extract from SAP system. Copyright SAP SE.
RSENQ051
- The roll up for InfoCube &1 has terminated ?The SAP error message RSENQ051 indicates that the roll-up process for an InfoCube has terminated unexpectedly. This can occur for various reasons, and understanding the cause is essential for resolving the issue. Here’s a breakdown of potential causes, solutions, and related information:
Causes:
- Data Consistency Issues: There may be inconsistencies in the data being processed, which can lead to roll-up failures.
- Locking Issues: The roll-up process may be unable to acquire necessary locks on the data, leading to termination.
- Memory Issues: Insufficient memory or resources on the application server can cause the roll-up to fail.
- Process Termination: The process may have been manually terminated or interrupted due to system issues.
- Configuration Issues: Incorrect settings in the InfoCube or the roll-up process can lead to failures.
- Data Volume: Large volumes of data being processed can lead to timeouts or resource exhaustion.
Solutions:
- Check Logs: Review the application logs (transaction SLG1) and the roll-up logs to identify specific errors or warnings that occurred during the roll-up process.
- Data Consistency Check: Use transaction RSA1 to check the consistency of the InfoCube and perform any necessary repairs.
- Increase Resources: If memory issues are suspected, consider increasing the memory allocation for the application server or optimizing the server performance.
- Lock Management: Ensure that no other processes are locking the InfoCube. You can use transaction SM12 to check for and manage locks.
- Re-run the Roll-Up: After addressing any identified issues, attempt to re-run the roll-up process.
- Adjust Roll-Up Settings: Review and adjust the settings for the roll-up process in the InfoCube configuration if necessary.
- Batch Job Monitoring: If the roll-up is scheduled as a batch job, monitor the job in transaction SM37 for any additional errors or issues.
Related Information:
By following these steps, you should be able to identify the cause of the RSENQ051 error and implement a solution to resolve it. If the issue persists, consider reaching out to SAP support for further assistance.
Get instant SAP help. Start your 7-day free trial now.
RSENQ050
A roll up is running for InfoCube &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSENQ049
Aggregate &1 being used as source for filling an aggregate
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSENQ052
The change run has been started already by user &1
What causes this issue? The change run for attributes and hierarchies has terminated. For reasons of consistency, you are not able to continue.System...
RSENQ053
The system is not able to fill the aggregates at this time
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.