Do you have any question about this error?
Message type: E = Error
Message class: RSDS - New DataSource
Message number: 222
Message text: DataSource &1 &2 is not configured for generic delta
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
RSDS222
- DataSource &1 &2 is not configured for generic delta ?The SAP error message RSDS222 indicates that a specific DataSource is not configured for generic delta. This typically occurs when you are trying to use a DataSource that is expected to support delta extraction, but it has not been set up correctly to do so.
Cause:
- DataSource Configuration: The DataSource in question is not configured to support generic delta extraction. This can happen if the DataSource is not set up with the necessary delta capabilities in the SAP system.
- Missing Delta Logic: The DataSource may not have the required delta logic implemented, which is necessary for tracking changes in the source data.
- Incorrect DataSource Type: The DataSource might be of a type that does not support delta extraction, such as a non-transactional DataSource.
Solution:
Check DataSource Configuration:
- Go to the DataSource in the SAP BW system (transaction code RSA1).
- Check the settings for the DataSource and ensure that it is configured for delta extraction. This includes verifying that the delta method is set correctly (e.g., using a timestamp or a change log).
Implement Delta Logic:
- If the DataSource is supposed to support delta but does not, you may need to implement the necessary delta logic. This could involve creating a custom delta mechanism or modifying the existing one.
- For generic delta, ensure that the DataSource is set up to capture changes in the source system.
Use a Different DataSource:
- If the DataSource is not intended to support delta extraction, consider using a different DataSource that does support it.
Consult Documentation:
- Review the SAP documentation for the specific DataSource to understand its capabilities and limitations regarding delta extraction.
Check for Notes and Updates:
- Look for any SAP Notes or updates related to the DataSource that might address known issues or provide guidance on configuration.
Related Information:
By following these steps, you should be able to resolve the RSDS222 error and configure your DataSource for generic delta extraction properly.
Get instant SAP help. Start your 7-day free trial now.
RSDS221
Last extracted request is '&1', not '&2'
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSDS220
Could not check destination &1 of external system &2
What causes this issue? While checking destination&v1& of type <ZK>external system</> , an error occurred.System Response It is ...
RSDS223
Exception NOT_FOUND with module RSA8_GET_POINTER_FOR_REQUEST
What causes this issue? When the module RSA8_GET_POINTER_FOR_REQUEST was called using destination &V1& for Request &V2& and DataSourc...
RSDS224
To date &1 earlier than From date &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.