Do you have any question about this error?
Message type: E = Error
Message class: RSDME -
Message number: 792
Message text: Activate content Info Object &1 to create BW DataSource for &2.
The specified BW content Info Object is not activated in the system.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Activate the relevant BW content Info Object to create BW datasources
for specified service.
Error message extract from SAP system. Copyright SAP SE.
RSDME792
- Activate content Info Object &1 to create BW DataSource for &2. ?The SAP error message RSDME792 indicates that there is an issue with activating the content of an InfoObject in the context of creating a BW DataSource. This error typically arises when the InfoObject has not been activated, which is necessary for the DataSource to be created successfully.
Cause:
- Inactive InfoObject: The primary cause of this error is that the InfoObject specified in the error message (denoted as
&1
) has not been activated in the system.- Transport Issues: If the InfoObject was recently transported from another system, it may not have been activated in the target system.
- Development Issues: The InfoObject may be in a development state and not yet fully configured or activated.
Solution:
To resolve the error, follow these steps:
Activate the InfoObject:
- Go to the SAP BW modeling tools or the Data Warehousing Workbench (transaction code RSA1).
- Navigate to the InfoObjects section.
- Locate the InfoObject specified in the error message (
&1
).- Right-click on the InfoObject and select "Activate" or use the activation option available in the toolbar.
Check for Dependencies:
- Ensure that all dependent objects (like InfoProviders, DataSources, etc.) are also activated if they rely on the InfoObject.
Recreate the DataSource:
- After activating the InfoObject, try to recreate the DataSource for the target object (
&2
) again.Transport Requests:
- If the InfoObject was transported, ensure that the transport request was completed successfully and that all necessary objects were included.
Check for Errors in Activation:
- If activation fails, check the activation logs for any additional errors that may provide more context on what went wrong.
Related Information:
By following these steps, you should be able to resolve the RSDME792 error and successfully create the BW DataSource.
Get instant SAP help. Start your 7-day free trial now.
RSDME791
No changes to save
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSDME790
Source &2 of Model &1 is detached from BW DataSource &3.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSDME793
&1 &2. Source &3 cannot be reset
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSDME794
Invalid/not-exisiting Source ID (GUID) for BW Datasource &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...