Do you have any question about this error?
Message type: E = Error
Message class: RSDDB - BIA Index Objects: Activate, Fill, Delete
Message number: 364
Message text: Check the status of the master data delta daemon (ID: '&1')
The process for indexing the new characteristic values is not yet
complete or could not be started. This process could therefore not be
successfully completed.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Check the status of the characteristic indexing job and why the job
could not be started. The name of the job is 'BI_BIA_NEWMD_INDEX'.
Error message extract from SAP system. Copyright SAP SE.
RSDDB364
- Check the status of the master data delta daemon (ID: '&1') ?The SAP error message RSDDB364 indicates an issue with the master data delta daemon, which is responsible for processing changes in master data in real-time. This error typically arises when the delta daemon is not running or has encountered an error, preventing it from processing updates to master data.
Cause:
- Delta Daemon Not Running: The most common cause is that the delta daemon for the specific master data object is not active.
- Configuration Issues: There may be configuration problems in the delta daemon settings.
- System Performance Issues: High system load or performance issues can cause the daemon to fail or become unresponsive.
- Database Locks: Locks on the database tables related to master data can prevent the delta daemon from processing updates.
- Transport Issues: If there have been recent transports that affect the master data, they may not have been properly activated.
Solution:
Check Delta Daemon Status:
- Use transaction code
RSD1
to check the status of the master data object.- Look for the delta daemon status and see if it is running.
Restart the Delta Daemon:
- If the delta daemon is not running, you can restart it. This can usually be done through transaction
RSCONN01
or by using the relevant administrative tools in your SAP system.Check Logs:
- Review the logs for the delta daemon to identify any specific errors or warnings that may indicate what went wrong. You can check the logs in transaction
SLG1
(Application Log).System Performance:
- Monitor system performance and resource usage. If the system is under heavy load, consider optimizing performance or scheduling the delta processing during off-peak hours.
Database Locks:
- Check for any locks on the database tables that might be affecting the delta daemon. You can use transaction
SM12
to view and manage locks.Configuration Review:
- Review the configuration settings for the delta daemon to ensure they are correct. This includes checking the settings in the DataSource and ensuring that the delta process is properly configured.
Transport Activation:
- If there have been recent transports, ensure that they have been activated correctly. You can check the transport logs for any issues.
Related Information:
Transaction Codes:
RSD1
: DataSource maintenance.RSCONN01
: Delta daemon management.SLG1
: Application log.SM12
: Lock management.SAP Notes: Check for any relevant SAP Notes that may address specific issues related to the delta daemon or master data processing.
Documentation: Refer to SAP Help documentation for detailed information on master data management and delta processing.
If the issue persists after following these steps, it may be necessary to consult with your SAP Basis team or SAP support for further assistance.
Get instant SAP help. Start your 7-day free trial now.
RSDDB363
Status check for master data delta daemon
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSDDB362
New characteristic values have not been indexed yet
What causes this issue? There are new attributes for InfoProvider characteristics. It has not yet been possible to load these into SAP NetWeaver BW A...
RSDDB365
Master data delta daemon (ID: '&1') terminated with errors
What causes this issue? A characteristic indexing process has terminated.System Response The system issues an error message and will not allow you t...
RSDDB366
Master data delta daemon could not be completed in the change run
What causes this issue? To ensure consistency between BW Accelerator data and the database, the master data indexing job must run successfully during...
Click on this link to search all SAP messages.