Message type: E = Error
Message class: RSDD_ZA - Messages from TREX Aggregate Area
Message number: 157
Message text: Check for connection of multiple BW systems to BW Accelerator
This check identifies how many BW systems are or were connected to the
BW accelerator. Only one BW system can be connected to the BW
accelerator at any given time. However, in some cases, for example, if
no production system is involved, more than one BW system can be
connected to the BW accelerator.
(See https://websmp101.sap-ag.de/~sapidb/011000358700001120232006E#16,,
"Must there be a 1:1 relationship between the BW instance and the BW
Accelerator?")
This check always returns a warning if the system identifies that more
than one BW system is connected.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Delete the data for the BW systems that are to be disconnected from the
BW accelerator, and disconnect all BW systems from the BW accelerator
with the exception of the BW system for which you want to continue to
use for this BW accelerator.
Error message extract from SAP system. Copyright SAP SE.
RSDD_ZA157
- Check for connection of multiple BW systems to BW Accelerator ?The SAP error message RSDD_ZA157 typically indicates an issue with the connection between multiple SAP BW (Business Warehouse) systems and the BW Accelerator. This error can arise due to various reasons, such as configuration issues, network problems, or system settings.
Cause:
Configuration Issues: The BW system may not be properly configured to connect to the BW Accelerator. This could involve incorrect settings in the BW system or the BW Accelerator. Network Problems: There may be network connectivity issues between the BW system and the BW Accelerator, preventing them from communicating effectively. Multiple Connections: If multiple BW systems are trying to connect to the same BW Accelerator, there may be conflicts or limitations in the configuration. Authorization Issues: The user or system may not have the necessary authorizations to establish a connection to the BW Accelerator. Version Compatibility: There may be compatibility issues between the versions of the BW system and the BW Accelerator.
Solution: Check Configuration: Verify the
Get instant SAP help. Sign up for our Free Essentials Plan.
RSDD_ZA156
Check for physical indexes with no assignment to logical index (InfoCube)
What causes this issue? This check searches for physical indexes that are not assigned to logical indexes or index joins and are therefore no longer ...
RSDD_ZA155
Check for checks that have been deactivated because of MemWatcher
What causes this issue? The system checks whether MemWatcher is activated and which functions it executes. Depending on the results, certain alert se...
RSDD_ZA158
Check for existing core files
What causes this issue? A TREX process has terminated and produced an analysis file (core file). You can use this file to analyze why the process ter...
RSDD_ZA159
Check of Hosts That Do Not Use Shared Memory
What causes this issue? Under certain circumstances, it is possible that the BWA is configured in such a way that it does not used shared memory. Thi...
Click on this link to search all SAP messages.