Message type: E = Error
Message class: RSDD_ZA - Messages from TREX Aggregate Area
Message number: 115
Message text: Status check of delta index
This check returns a list of indexes whose delta index is too large.
If the number of documents in the main index exceeds 5,000,000, the
relative parameters are used as reference parameters. The index fulfills
the criteria of the check in the following cases:
The volume of storage used by the delta index is more than 10% of the
volume of storage used by the main index (technical parameter
error_idx_mem_size_pct uses 10%).
The number of documents in the delta index is more than 10% of the
number of documents in the main index (technical parameter error_
idx_num_docs_pct uses 10%).
If the number of documents in the main index is less than or equal to 5
,000,000, the absolute parameters are used as reference parameters. The
index fulfills the criteria of the check in the following cases:
The volume of storage used by the delta index is larger than 200
megabytes (technical parameter error_mem is 200 megabytes in size).
The number of documents in the delta index is greater than 50,000
(technical parameter error_num_docs contains 50,000 documents).
If the <ZK>autoMerge</> function (automatic merging of the main index
with the delta index) of the MemWatcher in SAP NetWeaver BW Accelerator
is activated, the check always returns the status <ZK>OK</>.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Follow the instructions of any action proposed.
Error message extract from SAP system. Copyright SAP SE.
RSDD_ZA115
- Status check of delta index ?The SAP error message RSDD_ZA115, which pertains to the status check of a delta index, typically occurs in the context of SAP BW (Business Warehouse) when there are issues with the delta process for InfoProviders, particularly when dealing with DataStore Objects (DSOs) or InfoCubes.
Cause: The error can be caused by several factors, including: Delta Queue Issues: The delta queue may not be processed correctly, leading to inconsistencies in the delta index. Data Load Failures: Previous data loads may have failed, leaving the delta index in an inconsistent state. Locking Issues: There may be locks on the data that prevent the delta index from being updated or checked. Configuration Errors: Incorrect settings in the InfoProvider or data source configuration can lead to issues with delta processing. System Performance: High system load or performance issues can also affect the processing of delta indices.
Solution: To resolve the RSDD_ZA115 error, you can follow these steps: Check Delta Queue: Use transaction code RSA7
Get instant SAP help. Sign up for our Free Essentials Plan.
RSDD_ZA114
Index status check
What causes this issue? Some of the indexes have an incorrect status.System Response The system issues an error message and will not allow you to co...
RSDD_ZA113
Check for master indexes with differing snapshots and syncpoints
What causes this issue? Some of the master indexes have inconsistent snapshots and syncpoints because replication was not started.System Response Th...
RSDD_ZA116
Queue status check
What causes this issue? Some of the queues have an incorrect status.System Response The system issues an error message and will not allow you to con...
RSDD_ZA117
Check of document status of queue
What causes this issue? Some of the queues have documents with an incorrect status.System Response The system issues an error message and will not a...
Click on this link to search all SAP messages.