Do you have any question about this error?
Message type: E = Error
Message class: RSDD_ZA - Messages from TREX Aggregate Area
Message number: 053
Message text: Server &1 does not have a functioning RFC connection to BW Accelerator
The application server &V1& of this system does not have an RFC
connection to BW Accelerator. From this server, queries cannot read data
from BW Accelerator, and status information cannot be obtained from BW
Accelerator. It is not possible to perform actions on BW Accelerator
either.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Restart the BW Accelerator servers. By doing this, the RFC servers for
all application servers of the current system are rebuilt. If this is
not successful, contact your system administrator.
Error message extract from SAP system. Copyright SAP SE.
RSDD_ZA053
- Server &1 does not have a functioning RFC connection to BW Accelerator ?The SAP error message RSDD_ZA053 indicates that there is an issue with the Remote Function Call (RFC) connection between the SAP BW (Business Warehouse) system and the BW Accelerator. This error typically arises when the BW Accelerator is not reachable or not properly configured.
Cause:
- Network Issues: There may be network connectivity problems between the BW system and the BW Accelerator.
- RFC Configuration: The RFC destination for the BW Accelerator may not be correctly configured or may be missing.
- BW Accelerator Status: The BW Accelerator may not be running or may be in a state that does not allow connections.
- Authorization Issues: The user credentials used for the RFC connection may not have the necessary authorizations.
- System Configuration: There may be configuration issues in the BW system or the BW Accelerator that prevent a successful connection.
Solution:
Check Network Connectivity:
- Ensure that the BW system can reach the BW Accelerator over the network. You can use tools like
ping
ortelnet
to test connectivity.Verify RFC Destination:
- Go to transaction
SM59
in the SAP GUI.- Check the RFC destination that points to the BW Accelerator. Ensure that it is correctly configured and test the connection using the "Test Connection" button.
Check BW Accelerator Status:
- Ensure that the BW Accelerator is up and running. You may need to check the logs or the management console of the BW Accelerator for any errors.
Review Authorizations:
- Ensure that the user used for the RFC connection has the necessary authorizations to access the BW Accelerator.
Check Configuration:
- Review the configuration settings in both the BW system and the BW Accelerator. Ensure that all necessary parameters are set correctly.
Restart Services:
- If everything seems correct but the issue persists, consider restarting the BW Accelerator services or the BW system.
Consult Logs:
- Check the system logs (transaction
SM21
) and the BW Accelerator logs for any additional error messages that might provide more context on the issue.Related Information:
By following these steps, you should be able to identify and resolve the issue causing the RSDD_ZA053 error message.
Get instant SAP help. Start your 7-day free trial now.
RSDD_ZA052
No servers have a functioning RFC connection to BW Accelerator
What causes this issue? None of the application servers belonging to this system has an RFC connection to BW Accelerator. As a result, queries cannot...
RSDD_ZA051
No problems exist
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSDD_ZA054
Notify your system administrator
What causes this issue? A problem that cannot be resolved automatically has occurred.System Response The system issues an error message and will not...
RSDD_ZA055
Index checks returned at least one error as result
What causes this issue? The results of the last run of index checks contain at least one error.System Response The system issues an error message an...
Click on this link to search all SAP messages.