Message type: E = Error
Message class: RSD_TREX - Messages from TREX Aggregate Area
Message number: 134
Message text: BWA index not set to 'active' for technical reasons ('&1')
For technical reasons, the SAP NetWeaver BW Accelerator Index has &1&
not been<ZK>activated</>
For technical reasons, the NetWeaver BW Accelerator index is not
available for reporting. You cannot change this setting manually. The
corresponding processes that set the BWA index to <ZK>inactive</> must
first be completed..
<ZK>N</>. The BWA index has been deactivated to complete the change run
without adjusting the data on the BWA server. To adjust the data in the
BWA server, execute program RSDDTREX_BIA_CR_POSTPROCESS with the ID of
the change run.
<ZK>C</>. The change run has not yet completed successfully.
<ZK>I</>. The InfoCube of the BWA index has been changed and
reactivated. You first need to make the adjustments for the BWA index
(transaction RSZV).
<ZK>S</>: One index in a table has been deleted and rebuilt. This
process has not yet completed successfully.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
RSD_TREX134
- BWA index not set to 'active' for technical reasons ('&1') ?The SAP error message RSD_TREX134 indicates that a BWA (Business Warehouse Accelerator) index is not set to 'active' due to certain technical reasons. This can occur for various reasons, and understanding the cause is essential for resolving the issue. Causes: Indexing Issues: The BWA index may not have been successfully created or updated due to errors during the indexing process. Data Consistency: There may be inconsistencies in the data that prevent the index from being activated. Technical Limitations: The BWA system may have reached certain technical limits, such as memory or storage constraints. Configuration Problems: Incorrect configuration settings in the BWA or BW system can lead to this error. Version Compatibility: There may be compatibility issues between the BW version and the BWA version. Solutions: Check Index Status: Use transaction code RSD1 to check the status of the BWA index. Ensure that the index is not in a 'failed' state. Rebuild the Index: If the index is not active,
Get instant SAP help. Sign up for our Free Essentials Plan.
RSD_TREX133
BWA indexes reactivated for reporting
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSD_TREX132
Change run with ID '&1' is not yet complete
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSD_TREX135
Adjustment of data for characteristic '&1' in BWA during postprocessing
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSD_TREX136
BWA index for InfoCube '&1' is "inactive". Read data from database.
What causes this issue? The setting in transaction RSDDB is "Query is sent to the database if the BWA index is inactive", and BWA index ...