Do you have any question about this error?
Message type: E = Error
Message class: RSCNV - Messages class for Metadata Remodeling Toolbox
Message number: 827
Message text: Time characteristics &1 cannot be filled with &2
Time characteristics can only be filled with time characteristics only.
It cannot be filled with characteristics whose type is not 'TIM'.
Remodeling cannot be performed.
If you want to fill the time characteristic with other type then you may
use Customer Exit for filling it.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
RSCNV827
- Time characteristics &1 cannot be filled with &2 ?The SAP error message RSCNV827 indicates that there is an issue with the time characteristics in your data processing. Specifically, it means that the time characteristic (denoted as &1) cannot be filled with the value (denoted as &2) you are trying to assign to it. This error typically occurs in the context of data extraction, transformation, or loading processes, particularly in SAP BW (Business Warehouse) or similar environments.
Cause:
Data Type Mismatch: The value you are trying to assign to the time characteristic does not match the expected data type or format. For example, if the time characteristic expects a date format and you are providing a string or an incorrect date format, this error will occur.
Invalid Value: The value being assigned may not be valid for the time characteristic. For instance, if the time characteristic is defined to accept only certain ranges of dates or times, and the value you are trying to assign falls outside of this range, the error will be triggered.
Configuration Issues: There may be issues with the configuration of the time characteristics in the data model or InfoObject settings. If the InfoObject is not set up correctly to handle the expected values, this error can arise.
Data Source Issues: If the data source from which you are extracting data has inconsistencies or errors, it may lead to this error when trying to load the data into the target InfoObject.
Solution:
Check Data Types: Verify that the data type of the value you are trying to assign matches the expected data type of the time characteristic. Ensure that date formats are consistent and valid.
Validate Values: Ensure that the value being assigned is valid for the time characteristic. Check for any constraints or ranges defined for the characteristic and make sure the value falls within those limits.
Review Configuration: Check the configuration of the InfoObject and ensure that it is set up correctly to accept the values you are trying to load. This includes checking the settings in the data model and any transformations that may be applied.
Data Source Review: Investigate the data source for any inconsistencies or errors. Ensure that the data being extracted is clean and adheres to the expected formats and values.
Debugging: If the issue persists, consider using debugging tools in SAP to trace the data flow and identify where the error is occurring. This can help pinpoint the exact cause of the issue.
Related Information:
SAP Notes: Check SAP Notes for any known issues or patches related to this error message. SAP frequently updates its knowledge base with solutions for common problems.
Documentation: Review the documentation for the specific InfoObject and data model you are working with to understand the expected formats and constraints for time characteristics.
Community Forums: Engage with SAP community forums or support channels where other users may have encountered similar issues and can provide insights or solutions.
By following these steps, you should be able to identify the cause of the RSCNV827 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
RSCNV826
Remodeling of IMO DSO is not supported
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSCNV825
Remodeling of IMO InfoCube is not supported
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSCNV828
Constant filling cannot be used for characteristic &
What causes this issue? InfoObject &V1& is a compounded characteristic, hence constant filling cannot be used.System Response Remodeling is ...