Do you have any question about this error?
Message type: E = Error
Message class: RSCNV - Messages class for Metadata Remodeling Toolbox
Message number: 017
Message text: ODSO partitioned at database level
ODSO table has been partitioned at a database level. So ODSO metadata
does not have this information. Hence if it is remodeled, the partition
will be over written.
System displays warning message.
User can ignore this message and continue with Remodeling. But he will
have to manually adjust the partitions after Remodeling is over.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
RSCNV017
- ODSO partitioned at database level ?The SAP error message RSCNV017 indicates that the Operational Data Store (ODS) is partitioned at the database level, which can lead to issues when trying to perform certain operations, such as data extraction or reporting. This error typically arises in the context of SAP BW (Business Warehouse) or SAP BW/4HANA environments.
Cause:
The error occurs when the ODS object is set up with database-level partitioning, and the system encounters a situation where it cannot handle the partitioning correctly. This can happen due to:
- Inconsistent Data Model: The data model may not be aligned with the partitioning strategy.
- Incorrect Configuration: The ODS object may not be configured properly to handle partitioned data.
- Data Extraction Issues: Problems during data extraction processes that involve partitioned tables.
- Database Constraints: Constraints or limitations imposed by the underlying database system regarding partitioned tables.
Solution:
To resolve the RSCNV017 error, you can take the following steps:
Check ODS Configuration:
- Review the configuration of the ODS object in the SAP BW system. Ensure that it is set up correctly for partitioning.
- Verify that the data model aligns with the partitioning strategy.
Review Data Extraction Processes:
- Check the data extraction processes that are being used. Ensure that they are compatible with the partitioned ODS.
- If necessary, adjust the extraction logic to accommodate the partitioning.
Database Administration:
- Consult with your database administrator to ensure that the database settings and configurations support the partitioning of the ODS.
- Check for any database-level constraints or issues that may be causing the error.
Rebuild or Reconfigure ODS:
- If the issue persists, consider rebuilding the ODS object or reconfiguring it to remove the partitioning if it is not necessary for your use case.
SAP Notes and Support:
- Check the SAP Support Portal for any relevant SAP Notes that may address this specific error. There may be patches or updates available that can resolve the issue.
- If you are unable to resolve the issue, consider reaching out to SAP Support for further assistance.
Related Information:
By following these steps, you should be able to diagnose and resolve the RSCNV017 error related to the ODS being partitioned at the database level.
Get instant SAP help. Start your 7-day free trial now.
RSCNV016
ODSO contains waiting requests in activation queue
What causes this issue? The ODSO contains requests that have not been activated.System Response The system returns an error message. The user cannot...
RSCNV015
InfoObject to be deleted is key field in ODSO
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSCNV018
Filling methods not supported because change log is not empty
What causes this issue? The change log is not empty. Remodeling involves a change of structure, which could lead to inconsistencies.System Response ...
RSCNV019
Delta extraction from ODSO to further targets is not complete
What causes this issue? Delta extraction is not complete from the ODSO to further data targets. Since Remodeling involves structural changes, data ex...
Click on this link to search all SAP messages.