Do you have any question about this error?
Message type: E = Error
Message class: RSAR - Data Transfer and Metadata Maintenance
Message number: 741
Message text: InfoObject & of communication structure still being used
The deletion of the communication structure for InfoSource &V2& is not
possible. InfoObject &V1& of the communication structure is still being
used. This use must be undone first.
Concretely the communication structure of an InfoSource can only be
deleted if there are no update rules for InfoCubes and no transfer
structures for source systems for this InfoSource.
Activity was finished without database change.
Check the use of your InfoSource &V2& in the transfer structures.
Delete all existing transfer structures of your InfoSource &V2&.
Check the use of your InfoSource &V2& in update rules for InfoCubes.
Delete all existing update rules for your InfoSource &V2&.
Afterwards, you can delete your communication structure for InfoSource
&v2&.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
RSAR741
- InfoObject & of communication structure still being used ?The SAP error message RSAR741 indicates that an InfoObject is still being used in a communication structure, which prevents certain operations from being performed, such as deleting or modifying the InfoObject. This typically occurs in the context of SAP BW (Business Warehouse) when you are trying to make changes to InfoObjects that are still referenced in various data models or structures.
Cause:
The primary cause of the RSAR741 error is that the InfoObject you are trying to modify or delete is still being referenced in one or more communication structures. Communication structures are used in data transfer processes (DTPs) and are essential for data extraction and loading processes in SAP BW.
Solution:
To resolve the RSAR741 error, you need to identify where the InfoObject is being used and take appropriate actions. Here are the steps you can follow:
Identify Usage:
- Use transaction code
RSA1
to access the Data Warehousing Workbench.- Navigate to the InfoObject in question and check its usage in communication structures.
- You can also use transaction
SE11
to check the database table or structure where the InfoObject is referenced.Check Communication Structures:
- Go to the relevant communication structures (e.g., in the DTPs or InfoPackages) and see if the InfoObject is included.
- You can find communication structures under the "Data Flow" section in the Data Warehousing Workbench.
Modify or Remove References:
- If the InfoObject is being used in a DTP or InfoPackage, you may need to modify the DTP or InfoPackage to remove the reference to the InfoObject.
- If the InfoObject is part of a transformation, you may need to adjust the transformation rules.
Deactivate or Delete:
- Once you have removed all references to the InfoObject, you can deactivate or delete the communication structures that were using it.
- After ensuring that the InfoObject is no longer in use, you should be able to proceed with your intended operation (e.g., deleting or modifying the InfoObject).
Transport Requests:
- If you are working in a development environment, ensure that any changes are included in transport requests if they need to be moved to other environments (e.g., QA, Production).
Related Information:
RSA1
(Data Warehousing Workbench), SE11
(Data Dictionary), and RSD1
(InfoObject Maintenance).By following these steps, you should be able to resolve the RSAR741 error and successfully manage your InfoObjects in SAP BW.
Get instant SAP help. Start your 7-day free trial now.
RSAR740
Necessary units/currency fields were highlighted
What causes this issue? You have highlighted quantities and/or value fields that require a unit/currency field. The field has to be highlighted.Syste...
RSAR739
Highlights for used fields set again
What causes this issue? You have unhighlighted fields, this is not allowed.System Response The highlighting of the fields used was reset.How to fix ...
RSAR742
No object for field & in position & (not transferred !)
What causes this issue? The specification of the InfoObject is missing in the field entered in position &V2& with the field name &V1&...
RSAR743
Change to source system not possible
What causes this issue? The change to RFC parameters is not possible for source systems with manual meta data adjustment and data transfer from files...