Message type: E = Error
Message class: RSAR - Data Transfer and Metadata Maintenance
Message number: 240
Message text: IDoc segment & could not be assigned to IDoc &
The transfer structure is assigned to IDoc &V2& as an IDoc segment for t
he data transfer between the source system and the Business Information
Warehouse.
This assignment failed.
IDoc segment &V1& not known to IDoc &V2&. Therefore, no data import can
take place from the source system for this InfoSource.
Check the SAP Support Portal for relevant notes and create a new problem
message if necessary.
Error message extract from SAP system. Copyright SAP SE.
RSAR240
- IDoc segment & could not be assigned to IDoc & ?The SAP error message RSAR240 typically indicates that there is an issue with the assignment of an IDoc segment to an IDoc type. This error can occur in various scenarios, particularly when dealing with data transfer processes, such as ALE (Application Link Enabling) or EDI (Electronic Data Interchange).
Cause: Incorrect IDoc Type or Segment: The IDoc segment being processed does not match the expected structure of the IDoc type. This can happen if the IDoc type has been changed or if the segment is not defined correctly in the IDoc structure. Missing Segment Definition: The segment definition may not exist in the system, or it may not be activated.
Configuration Issues: There may be configuration issues in the IDoc processing settings, such as incorrect mapping or settings in the partner profiles. Data Issues: The data being sent may not conform to the expected format or structure, leading to assignment failures.
Solution: Check IDoc Type and Segment Definitions: Use
Get instant SAP help. Sign up for our Free Essentials Plan.
RSAR239
Name of BW source system is not defined (client &)
What causes this issue? To produce communication between the source system and Business Warehouse, the logical system names must be assigned. No such...
RSAR238
IDoc type for source system & is not available
What causes this issue? An IDoc is required as the carrier for the transfer structure in data im porting. This IDoc has not been created for source s...
RSAR241
Rec. length of control file & does not correspond to that of IDOC seg &
What causes this issue? A record length is given in control file &V1&, that does not agree with the length of the transfer structure. A trans...
RSAR242
The transfer structures and template do not have fields
What causes this issue? The <LS>transfer structure</> and the <LS>InfoSource template</> are both error-free. Therefore, you ...
Click on this link to search all SAP messages.