Do you have any question about this error?
Message type: E = Error
Message class: RMXTAPI - TMS-API: Messages for Trial API
Message number: 082
Message text: Recipe does not contain primary output/primary output is not a material
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
RMXTAPI082
- Recipe does not contain primary output/primary output is not a material ?The SAP error message RMXTAPI082 indicates that there is an issue with a recipe in the SAP system, specifically that the recipe does not contain a primary output or that the primary output is not defined as a material. This error typically occurs in the context of production planning and recipe management within SAP, particularly in the SAP Production Planning (PP) and SAP Recipe Management (RM) modules.
Cause:
- Missing Primary Output: The recipe you are trying to use does not have a primary output defined. In SAP, a primary output is a key product that is produced by the recipe.
- Incorrect Configuration: The primary output may be defined, but it is not set up correctly as a material in the system. This could mean that the material is not created or activated in the system.
- Recipe Configuration Issues: There may be issues with how the recipe is configured, such as missing links to the material master or incorrect settings in the recipe itself.
Solution:
Check Recipe Configuration:
- Go to the recipe in question and verify that a primary output is defined. You can do this by navigating to the recipe management transaction (e.g., C201 or C202).
- Ensure that the primary output is correctly linked to a material that exists in the material master.
Define Primary Output:
- If the primary output is missing, you need to define it. In the recipe, specify the primary output material that should be produced.
Verify Material Master:
- Check the material master for the primary output. Ensure that the material is created and activated in the system. You can do this using transaction code MM03 to view the material details.
- Ensure that the material type is appropriate for the output you are trying to produce.
Check for Errors in Recipe:
- Review the recipe for any other errors or inconsistencies that might be causing the issue. This includes checking for missing components or incorrect settings.
Consult Documentation:
- Refer to SAP documentation or help resources for more detailed guidance on recipe management and troubleshooting.
Related Information:
By following these steps, you should be able to resolve the RMXTAPI082 error and ensure that your recipe is correctly configured with a valid primary output.
Get instant SAP help. Start your 7-day free trial now.
RMXTAPI081
Recipe &1 does not contain a formula or a primary output
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RMXTAPI080
Cannot delete &1; trial type is used in trials
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RMXTAPI083
Trial quantity (&1 &2) is not within lot-size range (&3-&4) of recipe
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RMXTAPI084
Planned execution date &1 is not within recipe validity period (&2-&3)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.