Do you have any question about this error?
Message type: E = Error
Message class: RMXMTRF - RMXM-TRF: Messages for Master Recipe Transformation
Message number: 200
Message text: Assignment of process parameter &1 to process instruction is not defined
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
RMXMTRF200
- Assignment of process parameter &1 to process instruction is not defined ?The SAP error message RMXMTRF200, which states "Assignment of process parameter &1 to process instruction is not defined," typically occurs in the context of process manufacturing or when working with process orders in SAP. This error indicates that there is a missing or incorrect assignment between a process parameter and a process instruction in the system.
Cause:
- Missing Configuration: The process parameter (e.g., a measurement or control parameter) has not been properly assigned to the corresponding process instruction in the configuration settings.
- Incorrect Master Data: The master data for the process order or the related process instruction may not be set up correctly.
- Process Instruction Not Defined: The specific process instruction that the system is trying to reference may not exist or may not be properly defined in the system.
- Versioning Issues: If there are multiple versions of process instructions or parameters, the system may be referencing an outdated or incorrect version.
Solution:
Check Process Parameter Assignment:
- Go to the configuration settings for process parameters and process instructions in SAP.
- Ensure that the process parameter in question is correctly assigned to the relevant process instruction.
Review Master Data:
- Check the master data for the process order, including the process instructions and parameters.
- Make sure that all necessary data is correctly defined and active.
Define Missing Process Instructions:
- If the process instruction does not exist, create it in the system.
- Ensure that all required fields and settings are filled out correctly.
Check for Version Conflicts:
- If there are multiple versions of process parameters or instructions, verify that the correct version is being used in the process order.
Consult Documentation:
- Review SAP documentation or help resources related to process order management and process parameters for additional guidance.
Testing:
- After making the necessary changes, test the process to ensure that the error no longer occurs.
Related Information:
C223
(to maintain process parameters) or C201
(to maintain process instructions) to check and update the relevant configurations.If the issue persists after following these steps, it may be beneficial to consult with your SAP support team or a functional consultant who specializes in process manufacturing.
Get instant SAP help. Start your 7-day free trial now.
RMXMTRF104
Process instruction cat. of CRD &1, class &2 changed; create chars again
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RMXMTRF103
Characteristic data was not saved for changed process instruction cat.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RMXMTRF201
Assignment tables for the process parameter are not defined correctly
What causes this issue? Errors occurred while reading the <ZK>(Assign) Process Parameter to Process Instruction Category</> assignment ta...
RMXMTRF202
Error while assigning the process instruction category
What causes this issue? Error while assigning characteristic &V1& of process instruction category &V2& to process parameter &V3&a...
Click on this link to search all SAP messages.