Do you have any question about this error?
Message type: E = Error
Message class: RMSRCPDIA - RMS-RCP: Message Package RMSRCPDIA - User Interface
Message number: 128
Message text: Stream of stage &2 is not used in any subsequent stage
The stage formula of stage &V2& of recipe &V1& contains a stream as an
output item that is not used in any of the stages that follow.
Consistency check ended with errors.
Use the stream in a subsequent stage formula. Perform the consistency
check for the recipe again.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
RMSRCPDIA128
- Stream of stage &2 is not used in any subsequent stage ?The SAP error message RMSRCPDIA128 indicates that a stream defined in a specific stage of a data flow is not being utilized in any subsequent stages. This typically occurs in the context of SAP Data Services or SAP Data Intelligence, where data flows are designed to process and transform data.
Cause:
- Unused Stream: The stream defined in the specified stage is not connected to any downstream stages, meaning that the data produced by this stage is not being passed on for further processing.
- Design Oversight: It may be a result of an oversight during the design of the data flow, where the developer intended to use the stream but forgot to connect it to the next stage.
- Conditional Logic: If there are conditional paths in the data flow, the stream may not be used in certain conditions, leading to this error.
Solution:
- Check Connections: Review the data flow design to ensure that the stream in question is properly connected to subsequent stages. If it is not, connect it to the appropriate stage where the data should be used.
- Remove Unused Stages: If the stream is genuinely not needed, consider removing the stage that produces it to simplify the data flow and eliminate the error.
- Review Logic: If the stream is conditionally used, ensure that the logic is correctly implemented so that the stream is utilized as intended.
- Documentation: Document the purpose of each stream and its connections to avoid confusion in future modifications.
Related Information:
By addressing the cause of the error and implementing the suggested solutions, you should be able to resolve the RMSRCPDIA128 error and ensure that your data flow operates as intended.
Get instant SAP help. Start your 7-day free trial now.
RMSRCPDIA127
Consistency indicator has not been set for recipe
What causes this issue? The <LS>Consistency</> indicator has not been set for recipe &V1&. Therefore, you cannot use the recipe a...
RMSRCPDIA126
Replacement of current preferred recipe terminated
What causes this issue? You have canceled the action. The primary output is already produced by a different recipe, for which you set the Preferred i...
RMSRCPDIA129
System successfully transferred calculated primary output data
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RMSRCPDIA130
Choose an equipment requirement
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...