Do you have any question about this error?
Message type: E = Error
Message class: RMSFRMCST - RMS-FRM: Message Package RMSFRMCST - Customizing
Message number: 034
Message text: Specification type &1 of &2 is not permitted for tab page &3
The specification type &V1& was not defined in Customizing for
<LS>Recipe Management</> as a permitted specification type for the
formula view &V3&.
If you have entered the specification in the view, the system removes
the entry.
If the system determined the specification in the formula explosion, it
filters it and all other specifications with specification types that
are not permitted out of the result of the explosion. You can see the
unfiltered result in the calculation log.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
RMSFRMCST034
- Specification type &1 of &2 is not permitted for tab page &3 ?The SAP error message RMSFRMCST034 typically occurs in the context of the SAP Retail Management System (RMS) when there is an issue with the specification type assigned to a certain object or tab page. This error indicates that the specification type you are trying to use is not permitted for the specified tab page.
Cause:
- Invalid Specification Type: The specification type you are trying to use is not allowed for the object or tab page you are working with. This could be due to configuration settings or business rules defined in the system.
- Configuration Issues: There may be a misconfiguration in the system settings that governs which specification types are allowed for certain objects or tab pages.
- Data Entry Error: The user may have inadvertently selected an incorrect specification type while entering data.
Solution:
- Check Configuration: Review the configuration settings for the specification types in the relevant customizing settings (transaction SPRO). Ensure that the specification type is correctly defined and permitted for the tab page in question.
- Use Valid Specification Type: If you are trying to enter data, ensure that you are selecting a specification type that is valid for the tab page you are working on. Refer to the documentation or help resources to identify the correct specification types.
- Consult Documentation: Check the SAP documentation or help resources for the specific module you are working with to understand the valid combinations of specification types and tab pages.
- Contact Support: If you are unable to resolve the issue, consider reaching out to your SAP support team or consulting with SAP support for further assistance.
Related Information:
By following these steps, you should be able to identify the cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
RMSFRMCST033
Event &1: Comp. type &2 is relevant for function, not for calculation
What causes this issue? In Customizing for <LS>Recipe Management</>, you have made the setting for the event &V1& that the compon...
RMSFRMCST032
Explosion scope &1: Explosion using substances/materials is not defined
What causes this issue? In Customizing for <LS>Recipe Management</>, no settings were made to specify whether the system should explode v...
RMSFRMCST050
Entry &1 is not permitted as pushbutton
What causes this issue? In Customizing for <LS>Recipe Management</>, only the values from the value range of the domain FRMLD_BUTTON can ...
RMSFRMCST051
Internal error in &1 after reading &2 at index &4, subrc: &3
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.