Do you have any question about this error?
Message type: E = Error
Message class: RMSFRMCST - RMS-FRM: Message Package RMSFRMCST - Customizing
Message number: 023
Message text: Component types assigned to explosion scopes do not exist
In Customizing for <ZK>Recipe Management</> you assign component types
to the individual explosion scopes for formula explosion. However, no
entries were found (table FRMLC_RES).
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
INCLUDE RMS_GEN_ADMIN OBJECT DOKU ID TX
INCLUDE RMS_GEN_CHECK_RMS_CUSTOM OBJECT DOKU ID TX
Error message extract from SAP system. Copyright SAP SE.
RMSFRMCST023
- Component types assigned to explosion scopes do not exist ?The SAP error message RMSFRMCST023 indicates that there are component types assigned to explosion scopes in the Recipe Management System (RMS) that do not exist in the system. This typically occurs when there is a mismatch or misconfiguration in the component types that are expected to be used in a specific context, such as a recipe or a production process.
Cause:
- Missing Component Types: The component types that are referenced in the explosion scope are not defined in the system.
- Incorrect Configuration: The configuration for the explosion scope may be incorrect, leading to references to non-existent component types.
- Data Migration Issues: If data has been migrated from another system or from an older version of SAP, some component types may not have been migrated correctly.
- Custom Development: If there are custom developments or enhancements, they may not be correctly aligned with the standard component types.
Solution:
- Check Component Types: Verify that the component types referenced in the explosion scope are correctly defined in the system. You can do this by navigating to the relevant configuration or master data areas in SAP.
- Update Explosion Scope: If the component types are missing, you may need to create them or update the explosion scope to reference existing component types.
- Review Configuration: Go through the configuration settings for the Recipe Management System to ensure that all necessary component types are properly assigned and configured.
- Data Consistency Check: If data migration is involved, perform a consistency check to ensure that all necessary data has been migrated and is intact.
- Consult Documentation: Refer to SAP documentation or help resources for guidance on how to manage component types and explosion scopes in RMS.
- Contact SAP Support: If the issue persists and you cannot resolve it, consider reaching out to SAP support for assistance.
Related Information:
C223
(for maintaining component types) or C201
(for maintaining explosion scopes) to check and update the relevant data.By following these steps, you should be able to identify the root cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
RMSFRMCST022
Table FRMLC_CPT_KIND could not be read or is empty
What causes this issue? Due to an internal error, table FRMLC_CPT_KIND could not be read or does not contain any entries.System Response The system ...
RMSFRMCST021
System could not read formula views (table FRMLC01)
What causes this issue? The system issues an error message and will not allow you to continue with this transaction until the error is resolved. Syst...
RMSFRMCST024
Table FRMLT_EXSC could not be read or is empty
What causes this issue? The system issues an error message and will not allow you to continue with this transaction until the error is resolved. Syst...
RMSFRMCST025
No entries exist in Customizing for events and component types
What causes this issue? In Customizing for <ZK>Recipe Management</> you define <DS:DE.FRMLE_ROLE_EVENT>events</> (calculation...