Do you have any question about this error?
Message type: E = Error
Message class: RMSC - Message Class for Compliance Check in the RM Workbench
Message number: 026
Message text: In recipe &1, formula &2 does not have a primary output
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
RMSC026
- In recipe &1, formula &2 does not have a primary output ?The SAP error message RMSC026 indicates that in a specific recipe (identified by &1), the associated formula (identified by &2) does not have a primary output defined. This is a common issue in SAP's Recipe Management or Product Lifecycle Management (PLM) modules, particularly when dealing with production recipes and formulas.
Cause:
- Missing Primary Output: The formula associated with the recipe does not have a primary output defined. In SAP, a primary output is essential for production planning and execution, as it indicates the main product that will be produced from the recipe.
- Incorrect Configuration: The formula may not have been set up correctly, or the primary output may have been inadvertently removed or not defined during the creation of the formula.
- Data Inconsistency: There may be inconsistencies in the data or configuration settings that prevent the system from recognizing a primary output.
Solution:
Check the Formula Configuration:
- Navigate to the formula associated with the recipe.
- Ensure that a primary output is defined. This can typically be done in the formula management screen where you can specify outputs.
- If there is no primary output, you will need to define one. This usually involves specifying the product that is the main output of the formula.
Review Recipe Settings:
- Go to the recipe in question and check its settings.
- Ensure that it is correctly linked to the formula and that the formula is active and correctly configured.
Consult Documentation:
- Review SAP documentation or help resources related to Recipe Management and Formula Management to ensure that you are following the correct procedures for defining outputs.
Testing:
- After making the necessary changes, test the recipe again to ensure that the error message no longer appears.
Consult with SAP Support:
- If the issue persists after checking the formula and recipe settings, consider reaching out to SAP support for further assistance. They may provide insights specific to your system configuration.
Related Information:
By following these steps, you should be able to resolve the RMSC026 error and ensure that your recipes and formulas are correctly configured for production.
Get instant SAP help. Start your 7-day free trial now.
RMSC025
Specification type &1 is not permitted
What causes this issue? You want to check a specification whose specification type &V1& is not permitted as an output.System Response The s...
RMSC024
Error occurred when defining diets
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RMSC027
Value for parameter &1 for determining the composition is required
What causes this issue? You have not entered a value for the parameter &V1& in the <ls> Parameters for Determining Composition</>...
RMSEQR000
&1 &2 &3 &4
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.