Do you have any question about this error?
Message type: E = Error
Message class: RMSA450QM - RMS: ATL QM Message Texts for QM Title Element
Message number: 009
Message text: Inspection method &1, &2 is not assigned to master insp. char. &1, &4
The inspection method is not assigned to the selected master inspection
characteristic.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Choose an inspection method that is assigned to the master inspection
characteristic. To display the possible inspection methods,
double-click the entry under master inspection characteristic twice.
Then choose <ZK>Inspection Methods.</>
Error message extract from SAP system. Copyright SAP SE.
RMSA450QM009
- Inspection method &1, &2 is not assigned to master insp. char. &1, &4 ?The SAP error message RMSA450QM009 indicates that there is an issue with the assignment of an inspection method to a master inspection characteristic (MIC) in the Quality Management (QM) module. Specifically, it suggests that the inspection method you are trying to use is not properly assigned to the specified master inspection characteristic.
Cause:
- Missing Assignment: The inspection method you are trying to use is not assigned to the master inspection characteristic in the system.
- Incorrect Configuration: There may be a configuration issue where the inspection method is not linked to the correct characteristic.
- Data Entry Error: There could be a typo or error in the input data when trying to create or modify the inspection plan.
Solution:
Check Assignment:
- Go to the transaction code
QMP1
(Create Master Inspection Characteristic) orQMP2
(Change Master Inspection Characteristic).- Verify that the inspection method is correctly assigned to the master inspection characteristic in question.
- If it is not assigned, you will need to add the appropriate inspection method.
Create or Modify Inspection Method:
- If the inspection method does not exist, you may need to create it using transaction code
QMT1
(Create Inspection Method).- Ensure that the inspection method is properly configured and meets the requirements for the master inspection characteristic.
Review Inspection Plan:
- Check the inspection plan associated with the material or process to ensure that it references the correct master inspection characteristic and inspection method.
- Use transaction code
QP01
(Create Inspection Plan) orQP02
(Change Inspection Plan) to review and modify as necessary.Consult Documentation:
- Review SAP documentation or help files related to Quality Management and master inspection characteristics for additional guidance on proper configuration.
Testing:
- After making the necessary changes, test the process again to ensure that the error does not occur.
Related Information:
Transaction Codes:
QMP1
- Create Master Inspection CharacteristicQMP2
- Change Master Inspection CharacteristicQMT1
- Create Inspection MethodQP01
- Create Inspection PlanQP02
- Change Inspection PlanSAP Notes: Check for any relevant SAP Notes that may address this specific error or provide additional troubleshooting steps.
User Roles: Ensure that you have the necessary authorizations to make changes to master inspection characteristics and inspection methods.
By following these steps, you should be able to resolve the RMSA450QM009 error and ensure that your inspection methods are correctly assigned to the relevant master inspection characteristics.
Get instant SAP help. Start your 7-day free trial now.
RMSA450QM008
No valid plant exists in Customizing for General Recipes
What causes this issue? No plants have been defined in Customizing.System Response The default value 0001 is set automatically.How to fix this error...
RMSA450QM007
Data is currently locked by another user
What causes this issue? Another user is processing the data. You can only display the data.System Response The system issues an error message and wi...
RMSA450QM010
No inspection method exists for master insp. char. &1, version &2
What causes this issue? You can only choose inspection methods that are assigned to the master inspection characteristic. No inspection methods are a...
RMSA450QM011
QM data is locked. Display mode only
What causes this issue? No inspection methods exist for this master inspection characteristic. Input help is, therefore, not available.System Respons...
Click on this link to search all SAP messages.