Do you have any question about this error?
Message type: E = Error
Message class: REISCA - Information System: General Functions
Message number: 001
Message text: Field catalog was not yet created
A method of the ALV Control is supposed to be executed. The prerequisite
for this method is that the field catalog was transferred to the
control. But the field catalog was not transferred.
The action terminates.
First call the CL_REIS_MEASUREMENT_ALV->DISPLAY( ) method in order to
transfer the field catalog.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
REISCA001
- Field catalog was not yet created ?The SAP error message REISCA001, which states "Field catalog was not yet created," typically occurs in the context of reporting or data extraction processes, particularly when working with the SAP Report Painter or Report Writer tools. This error indicates that the system is unable to find the necessary field catalog that defines the structure and layout of the report.
Cause:
- Field Catalog Not Defined: The field catalog, which contains the definitions of the fields to be used in the report, has not been created or is missing.
- Incorrect Report Configuration: The report may not be properly configured to reference an existing field catalog.
- Authorization Issues: The user may not have the necessary authorizations to access or create the field catalog.
- System Issues: There may be underlying system issues or inconsistencies that prevent the field catalog from being recognized.
Solution:
Create the Field Catalog:
- Go to the transaction code for the report (e.g., GRR1 for Report Painter).
- Create a new field catalog or modify an existing one to include the necessary fields.
- Ensure that the field catalog is saved and activated.
Check Report Configuration:
- Verify that the report is correctly configured to use the appropriate field catalog.
- Ensure that the report layout is set up to reference the correct field catalog.
Authorization Check:
- Ensure that the user has the necessary authorizations to create or modify field catalogs.
- Consult with your SAP security team if there are any authorization issues.
System Check:
- If the issue persists, check for any system inconsistencies or errors that may be affecting the report generation.
- Consider running a system check or consulting with your SAP Basis team for further investigation.
Consult Documentation:
- Refer to SAP documentation or help resources for specific guidance on creating and managing field catalogs in your version of SAP.
Related Information:
If the problem continues after trying these solutions, it may be beneficial to reach out to SAP support or your internal SAP team for further assistance.
Get instant SAP help. Start your 7-day free trial now.
REISCA000
Field name &1 not found
What causes this issue? You tried to set a filter on a field name that does not exist. The &V1& field is not in the field catalog.System Resp...
REF_CALLER_T104
&1: VARNUMH &2 not deleted marked in DB-Table &3
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
REISCA002
Output options
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
REISCA003
Period/key date
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.