Do you have any question about this error?
Message type: E = Error
Message class: R8 - Messages from the meta data generation
Message number: 422
Message text: The DataSource type &1 of DataSource &2 is not permitted
You tried to assign an invalid type to the DataSource. The following
types are valid:
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
'MSD' for DataSources that potentially extract attributes.The DataSource cannot be saved as it is now.
Assign the DataSource to a valid type.
Error message extract from SAP system. Copyright SAP SE.
R8422
- The DataSource type &1 of DataSource &2 is not permitted ?The SAP error message R8422 indicates that there is an issue with the DataSource type being used in your SAP system. Specifically, it states that the DataSource type of the specified DataSource is not permitted. This error typically arises in the context of data extraction processes, particularly when working with SAP BW (Business Warehouse) or SAP Data Services.
Cause:
- Invalid DataSource Type: The DataSource type specified in the error message is not allowed for the operation you are trying to perform. This could be due to a mismatch between the DataSource type and the expected type for the target system or process.
- Configuration Issues: The DataSource may not be properly configured in the SAP system, or it may not be activated.
- Authorization Issues: The user may not have the necessary authorizations to access or use the specified DataSource.
- DataSource Type Restrictions: Certain DataSource types may have restrictions on their usage, depending on the context (e.g., extraction, replication).
Solution:
- Check DataSource Type: Verify the type of the DataSource in question. Ensure that it is compatible with the operation you are trying to perform. You can check this in the DataSource settings in the SAP BW or Data Services environment.
- Review Configuration: Ensure that the DataSource is properly configured and activated. You can do this by navigating to the DataSource in the SAP BW system and checking its settings.
- User Authorizations: Check the authorizations of the user executing the operation. Ensure that the user has the necessary permissions to access and use the DataSource.
- Consult Documentation: Refer to SAP documentation or notes related to the specific DataSource type to understand any restrictions or requirements that may apply.
- Contact SAP Support: If the issue persists after checking the above points, consider reaching out to SAP support for further assistance. They may provide insights specific to your system configuration or version.
Related Information:
By following these steps, you should be able to identify the cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
R8421
The long text of DataSource &1 is not maintained in the language &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
R8420
The medium text of DataSource &1 is not maintained in language &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
R8423
The view &1 of DataSource &2 is not active
What causes this issue? The view that you have assigned to the DataSource, and that you want to use as an extractor, is inactive. Only active views (...
R8424
The extraction view &1 of DataSource &2 has the wrong type
What causes this issue? You want to use view &v1& to extract data. However, this view is of the wrong type. Only transparent tables and datab...
Click on this link to search all SAP messages.