Do you have any question about this error?
Message type: E = Error
Message class: R7I - InfoProvider
Message number: 075
Message text: Assignment of DeltaProviders to involved InfoProviders
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
The InfoProviders that are assembled together to form a MultiProvider
can work together in pairs as delta InfoProviders.
That means that one of the InfoProviders contains cached data for a
logical dataset, and the other InfoProvider contains the new dataset
delta, which has not yet been posted in the first InfoProvider.
You can create pairs of InfoProviders in the current dialog box (for
delta caching).
Before you can create a delta pair, you must ensure that both of the
InfoProviders involved support delta caching.
You also have to specify the name of an ABAP delta class. This class
must support the IF_RSD_DELTAPAIR interface.
Error message extract from SAP system. Copyright SAP SE.
R7I075
- Assignment of DeltaProviders to involved InfoProviders ?The SAP error message R7I075 typically relates to issues with the assignment of DeltaProviders to involved InfoProviders in the context of SAP BW (Business Warehouse) or SAP BW/4HANA. This error can occur during the process of data extraction, transformation, or loading (ETL) when there are inconsistencies or misconfigurations in the data flow setup.
Cause:
- Incorrect Delta Configuration: The DeltaProvider may not be correctly configured or assigned to the InfoProvider, leading to issues in data extraction.
- Missing or Inactive Delta Process: The delta process for the InfoProvider might be inactive or not properly set up.
- Inconsistent Data Flow: There may be inconsistencies in the data flow definitions, such as missing links between the DeltaProvider and the InfoProvider.
- Transport Issues: If changes were transported from one system to another, there might be inconsistencies in the configuration.
- Version Mismatch: The version of the DeltaProvider may not match the version of the InfoProvider.
Solution:
- Check Delta Configuration: Verify the configuration of the DeltaProvider and ensure it is correctly assigned to the relevant InfoProviders.
- Activate Delta Process: Ensure that the delta process for the InfoProvider is active. You can do this in the Data Warehousing Workbench (transaction RSA1).
- Review Data Flow: Check the data flow definitions to ensure that all necessary links between the DeltaProvider and InfoProvider are correctly established.
- Transport Consistency: If the issue arose after a transport, check the transport logs and ensure that all necessary objects were transported correctly.
- Recreate Delta Process: If the issue persists, consider recreating the delta process for the InfoProvider.
- Check for Notes and Patches: Look for any SAP Notes or patches that may address known issues related to this error message.
Related Information:
By following these steps, you should be able to identify and resolve the issue related to the R7I075 error message in SAP BW.
Get instant SAP help. Start your 7-day free trial now.
R7I074
Only enter DeltaProvider with delta pair class
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
R7I073
Interface &1 needed for delta pairs is not in the system
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
R7I076
Program ID &2 used for InfoProvider &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
R7I077
Error while deleting the generated program for InfoCube &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.