Do you have any question about this error?
Message type: E = Error
Message class: R7I - InfoProvider
Message number: 072
Message text: &1 is not a delta cache provider; change the entry
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
R7I072
- &1 is not a delta cache provider; change the entry ?The SAP error message R7I072 indicates that the system is trying to access a delta cache provider that is not configured correctly or does not exist. This error typically occurs in the context of SAP BW (Business Warehouse) or SAP HANA when dealing with data extraction and delta processes.
Cause:
- Incorrect Delta Cache Configuration: The delta cache provider specified in the system is either not set up or is incorrectly configured.
- Missing Provider: The delta cache provider that the system is trying to use does not exist in the system.
- DataSource Issues: The DataSource may not be properly defined or activated, leading to issues in accessing the delta cache.
- Transport Issues: If the configuration was transported from another system, it may not have been set up correctly in the target system.
Solution:
Check Delta Cache Configuration:
- Go to the DataSource settings in the SAP BW system.
- Verify that the delta cache provider is correctly defined and active.
- Ensure that the DataSource is set up to use the correct delta mechanism.
Verify DataSource Activation:
- Ensure that the DataSource is activated in the SAP BW system.
- If it is not activated, activate it and check if the error persists.
Check for Missing Providers:
- Use transaction code
RSA1
to access the Data Warehousing Workbench.- Navigate to the DataSource and check if the delta cache provider is listed and correctly configured.
Review Transport Requests:
- If the configuration was transported, check the transport logs for any errors or issues during the transport process.
- Ensure that all necessary objects were included in the transport request.
Consult SAP Notes:
- Search for relevant SAP Notes that may address this specific error. SAP frequently updates its knowledge base with solutions for common issues.
Recreate Delta Cache:
- If the delta cache provider is corrupted, consider recreating it. This may involve deleting the existing cache and allowing the system to rebuild it.
Related Information:
Transaction Codes:
RSA1
- Data Warehousing WorkbenchRSC1
- Create DataSourceRSC2
- Change DataSourceRSC3
- Display DataSourceSAP BW Documentation: Review the official SAP BW documentation for detailed information on delta processes and cache management.
SAP Community: Engage with the SAP Community forums to see if other users have encountered similar issues and what solutions they have found.
If the problem persists after trying the above solutions, it may be beneficial to consult with your SAP Basis or BW team for further investigation, or to reach out to SAP support for assistance.
Get instant SAP help. Start your 7-day free trial now.
R7I071
Interface &1 needed for delta cache is not in the system
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
R7I070
Class &1 does not support interface &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
R7I073
Interface &1 needed for delta pairs is not in the system
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
R7I074
Only enter DeltaProvider with delta pair class
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.