Do you have any question about this error?
Message type: E = Error
Message class: R7B - BW Metadata (InfoCube, InfoObject, InfoObject catalog)
Message number: 290
Message text: Output length of InfoObject &1 is invalid
If an InfoObject is selected as a UUID, it has a fixed output length of
&V2&.
The InfoObject cannot be activated.
Set the length of the InfoObjects to &V2&.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
R7B290
- Output length of InfoObject &1 is invalid ?The SAP error message R7B290, which states "Output length of InfoObject &1 is invalid," typically occurs in the context of SAP BW (Business Warehouse) or SAP BI (Business Intelligence) when there is an issue with the configuration of an InfoObject. This error indicates that the output length defined for a specific InfoObject is not valid, which can lead to problems when trying to display or process data related to that InfoObject.
Cause:
- Invalid Output Length: The output length for the InfoObject may have been set incorrectly. This can happen if the length exceeds the maximum allowed value or is set to a negative number.
- Data Type Mismatch: The data type of the InfoObject may not match the expected format, leading to an invalid output length.
- Changes in InfoObject Definition: If the InfoObject was modified (e.g., changing its data type or length) without properly adjusting the related settings, it can lead to this error.
- Transport Issues: If the InfoObject was transported from one system to another, there may be inconsistencies in the configuration.
Solution:
Check InfoObject Definition:
- Go to the InfoObject maintenance transaction (e.g., RSA1 or RSD1).
- Locate the InfoObject in question and check its properties, specifically the output length.
- Ensure that the output length is set correctly according to the data type and the requirements of your application.
Adjust Output Length:
- If the output length is incorrect, modify it to a valid value. The output length should be appropriate for the data type (e.g., CHAR, NUMC, etc.).
- Save the changes and activate the InfoObject.
Review Data Type:
- Ensure that the data type of the InfoObject is appropriate for the data it is intended to hold. If necessary, change the data type and adjust the output length accordingly.
Check for Transport Issues:
- If the InfoObject was recently transported, verify that all related objects and settings were transported correctly.
- If discrepancies are found, consider re-transporting the InfoObject or manually correcting the settings.
Re-activate the InfoObject:
- After making changes, re-activate the InfoObject to ensure that the changes take effect.
Test the Changes:
- After making the necessary adjustments, test the InfoObject in the relevant reports or queries to ensure that the error no longer occurs.
Related Information:
By following these steps, you should be able to resolve the R7B290 error and ensure that the InfoObject is configured correctly for use in your SAP BW/BI environment.
Get instant SAP help. Start your 7-day free trial now.
R7B289
Length of InfoObject &1 is invalid; InfoObject is selected as UUID
What causes this issue? If an InfoObject is selected as a UUID, it has a fixed length of &V2&.System Response The InfoObject cannot be activ...
R7B288
Characteristic &1 has appends. Cannot delete
What causes this issue? Characteristic &V1& has appends. Characteristic &V1& cannot be deleted.System Response Deletion of character...
R7B291
InfoObject &1 is compounded and selected as UUID
What causes this issue? InfoObject &V1& is selected as a UUID. Therefore it must not be compounded.System Response InfoObject &V1& c...
R7B292
Characteristic &1: No determination of new SIDs for attributes
What causes this issue? The DDIC object does not exist in an active version.System Response Activation of the characteristic is not executed.How to ...
Click on this link to search all SAP messages.