Do you have any question about this error?
Message type: E = Error
Message class: QT - QM: Inspection during production (with inspection points)
Message number: 001
Message text: The plant presetting is not completely maintained in the cust. applic.
The designation of the inspection point/user-field combination is
missing for plant &V1& in the data block for inspection points.
The system determines the plant on the basis of the proposal parameters
or the inspection lot.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Make sure the inspection point data has been maintained in
<DS:SIMG.SIMG_CFMENUOLQSOQS1>QM Customizing</> for plant settings.
Error message extract from SAP system. Copyright SAP SE.
QT001
- The plant presetting is not completely maintained in the cust. applic. ?The SAP error message QT001, which states "The plant presetting is not completely maintained in the customer application," typically occurs in the context of Quality Management (QM) or when dealing with quality notifications and inspections. This error indicates that there are missing configurations or settings related to the plant in the customer application.
Cause:
- Incomplete Configuration: The plant settings for quality management may not be fully configured in the system. This could include missing entries in the configuration tables or settings that have not been maintained.
- Missing Master Data: The relevant master data (such as material master, vendor master, or plant master) may not be properly set up for the specific plant.
- Quality Management Settings: The quality management settings for the plant may not be activated or may be incomplete.
- User Authorizations: The user may not have the necessary authorizations to access or modify the plant settings.
Solution:
- Check Plant Settings: Go to the configuration settings in SAP and verify that all necessary plant settings for quality management are maintained. This can typically be done in the following path:
- SPRO ? Quality Management ? Quality Planning ? Maintain Plant Settings
- Maintain Master Data: Ensure that all relevant master data for the plant is correctly maintained. This includes:
- Material Master: Check the quality management views.
- Vendor Master: Ensure that the vendor is linked to the correct plant.
- Activate Quality Management: If quality management is not activated for the plant, you may need to activate it. This can be done in the configuration settings.
- Check Authorizations: Ensure that the user has the necessary authorizations to access and modify the plant settings. This may involve checking user roles and profiles.
- Consult Documentation: Refer to SAP documentation or help files for specific details on the configuration required for your version of SAP.
Related Information:
SPRO
for configuration, MM02
for material master changes, or MK01
for vendor master changes.By following these steps, you should be able to identify and resolve the cause of the QT001 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
QST086
No printer could be determined for the printing of the storage list
What causes this issue? The storage list is printed automatically at the start of a stability study. However, the system could not determine a printe...
QST085
No additional data exists for notification &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
QT002
The insp. point ident. is not completely maintained in the cust. applic.
What causes this issue? There is no entry available in Customizing for the inspection point/user-field combination &V1&.System Response The ...
QT003
The insp. point ident. is not completely maintained in the cust. applic.
What causes this issue? There is no entry available in Customizing for the inspection point/user-field combination &V1& in language &V2&a...