Message type: E = Error
Message class: QE - RM-QSS Fehlertexte zur Ergebniserfassung
Message number: 733
Message text: No QM STI evaluation can be carried out for characteristic &1
You tried to carry out a <ZH>QM-STI evaluation</> for characteristic
&V1&. To do so, the following preconditions must be fulfilled:
Confirmation of <ZH>measured values</> must be defined.
<ZH>Individual results</> must be defined.
At least one valid value must have been entered.
The function was not carried out.
Select a characteristic that fulfills the above preconditions.
Error message extract from SAP system. Copyright SAP SE.
QE733
- No QM STI evaluation can be carried out for characteristic &1 ?The SAP error message QE733 "No QM STI evaluation can be carried out for characteristic &1" typically occurs in the context of Quality Management (QM) when the system is unable to perform a Statistical Test Inspection (STI) evaluation for a specific characteristic. This can happen for several reasons, and understanding the cause is essential for resolving the issue. Causes: Characteristic Configuration: The characteristic in question may not be properly configured for statistical evaluation. This includes settings in the master data for the characteristic that may not allow for STI. Missing Data: There may be insufficient data available for the characteristic to perform the evaluation. This could be due to missing inspection lots or results. Incorrect Inspection Plan: The inspection plan associated with the characteristic may not be set up correctly, or the characteristic may not be included in the plan. Statistical Control Settings: The settings for statistical control in the quality management module may not
Get instant SAP help. Sign up for our Free Essentials Plan.
QE732
No run-chart can be displayed for characteristic &1
What causes this issue? You tried to display a <ZH>run-chart</> for characteristic &V1&. To do so, the following preconditions mu...
QE731
Data for the run-chart is inconsistent
What causes this issue? The data for the run-chart is inconsistent. Examples When the function module was called, no suitable table was found. When t...
QE740
No data could be exported
What causes this issue? You tried to export data from the quality control chart for statistical evaluation. This is only possible for data that has a...
QE750
First exit the current results processing session
What causes this issue? The inspection lot &V1& is blocked by the current transaction.System Response You cannot continue processing the usa...
Click on this link to search all SAP messages.