Message type: E = Error
Message class: QD - Message-Id. für Dynamisierung
Message number: 233
Message text: The combination inspection severity and AQL is not available
The sampling scheme &V1& does not contain the entered combination of
inspection severity and AQL value.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
QD233
- The combination inspection severity and AQL is not available ?The SAP error message QD233, which states "The combination inspection severity and AQL is not available," typically occurs in the context of quality management (QM) when you are trying to perform an inspection lot or quality inspection that involves a specific combination of inspection severity and Acceptable Quality Level (AQL) that has not been defined in the system.
Cause: Missing Configuration: The most common cause of this error is that the combination of inspection severity and AQL has not been configured in the system. This can happen if the quality management settings have not been properly set up for the material or inspection type you are working with. Incorrect AQL or Severity: The AQL or inspection severity being used may not be valid for the specific inspection lot or material. Master Data Issues: There may be issues with the master data related to the material, such as missing quality management views or incorrect settings.
Solution: Check
Get instant SAP help. Sign up for our Free Essentials Plan.
QD232
The maximum value is 100
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
QD231
You can only enter up to three digits after the decimal point
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
QD234
You have entered a value greater than 5 for the k factor
What causes this issue? When you determine a k factor using, for example, the Wilrich-Nomogramm, then you cannot enter a value that is greater than 5...
QD235
You cannot enter a k factor greater than 100
What causes this issue? You cannot enter a k factor that is greater than 100. A value of this size is not realistic. When you use a Wilrich Nonogramm...