Do you have any question about this error?
Message type: E = Error
Message class: QC - QM: Certificates
Message number: 070
Message text: The table for the origins of the values is inconsistent
The indicator for the inspection lot selection has not been set. You
are attempting, however, to access inspection lots with the specified
function module.
Processing cannot be continued for this characteristic.
Ensure that the table containing the characteristic value origins is
maintained consistently.
Error message extract from SAP system. Copyright SAP SE.
QC070
- The table for the origins of the values is inconsistent ?The SAP error message QC070, which states "The table for the origins of the values is inconsistent," typically occurs in the context of Quality Management (QM) within SAP. This error indicates that there is an inconsistency in the data related to the origins of values in the quality inspection process.
Cause:
- Data Inconsistency: The error often arises when there are discrepancies in the data stored in the tables that manage the origins of values, such as inspection results or quality notifications.
- Missing or Incorrect Configuration: If the configuration settings for quality management or the specific inspection plan are not set up correctly, it can lead to inconsistencies.
- Corrupted Data: Sometimes, data corruption or incomplete data entries can lead to this error.
- Changes in Master Data: If there have been recent changes to master data (like material master, inspection plans, etc.) that have not been properly updated in related tables, it can cause inconsistencies.
Solution:
- Check Configuration: Review the configuration settings in the Quality Management module to ensure that they are set up correctly. This includes checking the inspection plans, quality info records, and any related settings.
- Data Consistency Check: Use transaction codes like
QC01
(Create Inspection Lot) orQC02
(Change Inspection Lot) to check for inconsistencies in the inspection lots. You can also use transactionSE11
to check the relevant database tables for inconsistencies.- Reprocess Data: If you identify any inconsistencies, you may need to reprocess the data. This could involve re-entering inspection results or correcting any erroneous entries.
- Use SAP Notes: Check the SAP Support Portal for any relevant SAP Notes that may address this specific error. There may be patches or updates that resolve known issues related to QC070.
- Consult Documentation: Review SAP documentation or help files related to Quality Management for additional insights on how to resolve this error.
- Contact SAP Support: If the issue persists after trying the above solutions, consider reaching out to SAP Support for further assistance.
Related Information:
QA32
(Display Inspection Lot), QA11
(Record Results), and QAC2
(Change Inspection Results).QALS
(Inspection Lot), QAMR
(Results Recording), and QAVE
(Value Origin).By following these steps, you should be able to identify and resolve the cause of the QC070 error in SAP.
Get instant SAP help. Start your 7-day free trial now.
QC069
No short text was found for class characteristic &1
What causes this issue? No short text was found for the class characteristic with the internal number &V1&.System Response The system issues...
QC068
No short text was found for characteristic &3 in certificate profile &2
What causes this issue? No short text was found for characteristic &V3&, (identifier: &V1&) in certificate profile &V2&.Syste...
QC071
The table for the origins of the values is inconsistent
What causes this issue? The indicator for the inspection lot selection is set. You are <ZH>not</> attempting, however, to access inspecti...
QC072
No certificate profile was found for object number &1
What causes this issue? Internal error.System Response The system issues an error message and will not allow you to continue with this transaction u...