Do you have any question about this error?
Message type: E = Error
Message class: PVJ - Messages for PRICAT (cf. VJ)
Message number: 315
Message text: The base unit of measure for EAN &1 (&2) is missing
The EAN/UPC exists in the catalog as an item (table productline)
without a base unit of measure (table produnits) existing for it.
The catalog contains errors and can therefore not be updated.
Ensure that the BAPI is supplied with data in line with the interface
description.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
PVJ315
- The base unit of measure for EAN &1 (&2) is missing ?The SAP error message PVJ315 indicates that there is a missing base unit of measure for a specific EAN (European Article Number) in the system. This error typically arises in the context of material management and inventory management when dealing with product data.
Cause:
- Missing Base Unit of Measure: The primary cause of this error is that the base unit of measure for the specified EAN is not defined in the material master data.
- Incorrect Material Master Data: The material master record may not have been properly maintained, leading to missing or incorrect entries for the base unit of measure.
- Data Migration Issues: If data was migrated from another system, there may have been issues during the migration process that resulted in incomplete data.
- Configuration Issues: There may be configuration issues in the system that prevent the base unit of measure from being recognized.
Solution:
Check Material Master Data:
- Go to the material master record (transaction code
MM03
).- Enter the material number and check the Basic Data view.
- Ensure that the base unit of measure is correctly defined.
Maintain Base Unit of Measure:
- If the base unit of measure is missing, you can maintain it by using transaction code
MM02
to edit the material master.- Navigate to the Basic Data view and enter the appropriate base unit of measure.
Check EAN Assignment:
- Ensure that the EAN is correctly assigned to the material in the material master.
- This can be checked in the Sales Organization Data or Plant Data views, depending on how the EAN is used.
Review Configuration:
- If the issue persists, review the configuration settings related to units of measure in the SAP system.
- Ensure that the unit of measure settings are correctly configured in the system.
Data Migration Review:
- If the data was migrated, review the migration process to ensure that all necessary fields were populated correctly.
Consult Documentation:
- Refer to SAP documentation or help resources for additional guidance on handling unit of measure issues.
Related Information:
MM03
- Display MaterialMM02
- Change MaterialMM01
- Create MaterialBy following these steps, you should be able to resolve the PVJ315 error and ensure that the base unit of measure for the specified EAN is correctly defined in the system.
Get instant SAP help. Start your 7-day free trial now.
PVJ314
Catalog &1 was not posted. Error in application log &2
What causes this issue? During updating of catalog &v1&, errors occurred that were saved in application log &v2&.System Response Cat...
PVJ313
Mandatory field &1 of structure &2 (&3, &4) does not contain data
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
PVJ316
The higher-level entry for the structure &2 (&1, &3, &4) is missing
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
PVJ317
Material &1 only contains the generated EAN/UPC &2
What causes this issue? Material &v1& does not have an EAN/UPC. As an EAN/UPC is needed for price catalog maintenance, EAN/UPC &v2& ...
Click on this link to search all SAP messages.