Do you have any question about this error?
Message type: E = Error
Message class: PPECHK - iPPE Consistency Check
Message number: 305
Message text: Rep. pt. &1 at &2 &3 backfl. no comp./act. bef. split to parallel struct.
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
PPECHK305
- Rep. pt. &1 at &2 &3 backfl. no comp./act. bef. split to parallel struct. ?The SAP error message PPECHK305 typically occurs in the context of Production Planning and Execution (PP) when dealing with backflushing in a parallel structure. This error indicates that there is an issue with the reporting point (rep. pt.) and the associated components or activities before the split to a parallel structure.
Cause:
The error message PPECHK305 can be caused by several factors, including:
- Missing Components: The system cannot find the necessary components or activities that should be associated with the reporting point.
- Incorrect Configuration: The configuration of the production process or the backflushing settings may not be set up correctly, leading to inconsistencies.
- Parallel Structure Issues: If the production process involves a parallel structure, there may be issues with how the components are split or managed in that structure.
- Master Data Issues: Problems with the master data, such as incorrect BOM (Bill of Materials) or routing definitions, can lead to this error.
Solution:
To resolve the PPECHK305 error, you can take the following steps:
- Check Reporting Point Configuration: Ensure that the reporting point is correctly configured and that all necessary components are defined.
- Verify Component Availability: Check if all components required for the backflushing process are available and correctly assigned to the reporting point.
- Review Parallel Structure Setup: If your production process involves a parallel structure, review the setup to ensure that it is correctly defined and that all splits are properly managed.
- Examine Master Data: Review the BOM and routing for the production order to ensure that they are accurate and complete. Make any necessary adjustments.
- Consult Documentation: Refer to SAP documentation or help resources for specific guidance on handling backflushing and parallel structures.
- Test in a Development Environment: If possible, replicate the issue in a development or test environment to identify the root cause without affecting production data.
Related Information:
If the problem persists after following these steps, it may be beneficial to consult with your SAP support team or a technical consultant who specializes in SAP PP.
Get instant SAP help. Start your 7-day free trial now.
PPECHK304
&1 &2 has not been assigned a supply area
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
PPECHK303
Different MRP areas in group of alternative lines: &1 in &2 and &3 in &4
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
PPECHK306
Reporting point missing at &1 &2 before splitting to parallel structures
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
PPECHK307
Reporting point &1(&2) and &3(&4) are at the same logical position
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.