Do you have any question about this error?
Message type: E = Error
Message class: PPE_INST - Messages for Geometric Instances
Message number: 020
Message text: ***************Lock Storage Instances (CL_PPELIINST_CNTL)****************
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
PPE_INST020
- ***************Lock Storage Instances (CL_PPELIINST_CNTL)**************** ?The SAP error message PPE_INST020 typically relates to issues with locking storage instances in the context of SAP's Production Planning and Detailed Scheduling (PP/DS) module. This error can occur when there is a problem with the locking mechanism that prevents the system from accessing or modifying certain data related to storage instances.
Cause:
- Concurrent Access: The error may arise when multiple users or processes are trying to access or modify the same storage instance simultaneously, leading to a lock conflict.
- System Configuration: Incorrect configuration of the locking mechanism or storage instance settings can also lead to this error.
- Database Issues: Problems with the underlying database, such as deadlocks or transaction issues, can cause locks to not be released properly.
- Long-Running Transactions: If a transaction takes too long to complete, it may hold locks longer than expected, causing other processes to fail.
Solution:
- Check Lock Entries: Use transaction code SM12 to check for existing lock entries. Identify if there are any locks that are preventing access to the storage instance and consider releasing them if they are no longer needed.
- Review User Activity: Investigate the activities of users or processes that may be causing the lock. If a specific user or job is holding the lock, coordinate with them to resolve the issue.
- Adjust Configuration: Review the configuration settings for the storage instances and locking mechanisms to ensure they are set up correctly.
- Database Maintenance: Perform database maintenance tasks to ensure that there are no underlying issues affecting the locking mechanism. This may include checking for deadlocks or optimizing database performance.
- Increase Timeout Settings: If long-running transactions are common, consider increasing the timeout settings for locks to allow more time for processes to complete.
- Consult SAP Notes: Check the SAP Support Portal for any relevant SAP Notes that may address this specific error or provide additional troubleshooting steps.
Related Information:
If the problem persists after trying the above solutions, it may be necessary to involve your SAP Basis team or SAP support for further investigation.
Get instant SAP help. Start your 7-day free trial now.
PPE_INST011
Geometric instance &1/&2 (&3) inconsistent in buffer
What causes this issue? While processing a user request, the system determined that the geometric instance &V1& of type &V2& with int...
PPE_INST010
*******Synchronize Buffer Tables (CL_PPELIINST_CNTL)**************
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
PPE_INST021
Geometric instance &1/&2 (&3) currently being processed by &4
What causes this issue? You want to process geometric instance &V1&/&V2&, which has the internal ID &V3&. However, this insta...
PPE_INST022
Error while locking geometric instance &1; contact system administration
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.