Do you have any question about this error?
Message type: E = Error
Message class: PMEVC_UI -
Message number: 406
Message text: Reference characteristic &1 at material &2 has initial field name
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
PMEVC_UI406
- Reference characteristic &1 at material &2 has initial field name ?The SAP error message PMEVC_UI406 typically indicates that there is an issue with a reference characteristic in the context of variant configuration. This error occurs when a reference characteristic is expected to have a field name, but it is found to be empty or uninitialized for a specific material.
Cause:
- Missing Field Name: The reference characteristic is not properly defined or initialized in the material master or the configuration profile.
- Incorrect Configuration: The configuration settings for the material may not be set up correctly, leading to the reference characteristic not being recognized.
- Data Inconsistency: There may be inconsistencies in the data related to the material or its characteristics, which can lead to this error.
Solution:
Check Characteristic Definition:
- Go to the transaction code
CT04
(Characteristic Maintenance) and verify that the reference characteristic is correctly defined and has a valid field name.- Ensure that the characteristic is assigned to the appropriate class and that it is marked as relevant for the material.
Review Material Master:
- Use transaction code
MM03
(Display Material) to check the material master data for the material in question. Ensure that all relevant characteristics are properly assigned and initialized.Configuration Profile:
- Check the configuration profile assigned to the material using transaction code
CU41
(Configuration Profile). Ensure that the reference characteristic is included and correctly configured.Recreate or Adjust the Configuration:
- If the issue persists, consider recreating the configuration profile or adjusting the settings to ensure that all characteristics are properly linked and initialized.
Data Consistency Check:
- Run a consistency check for the material and its characteristics to identify any discrepancies. This can often be done through transaction codes like
CU50
(Configuration Simulation) orCU60
(Configuration Check).Consult Documentation:
- Refer to SAP documentation or help resources for additional guidance on handling variant configuration and characteristic definitions.
Related Information:
Transaction Codes:
CT04
: Characteristic MaintenanceMM03
: Display MaterialCU41
: Configuration ProfileCU50
: Configuration SimulationCU60
: Configuration CheckSAP Notes: Check for any relevant SAP Notes that may address this specific error or provide additional troubleshooting steps.
SAP Community: Engage with the SAP Community forums for insights from other users who may have encountered similar issues.
By following these steps, you should be able to identify and resolve the PMEVC_UI406 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
PMEVC_UI405
Reference characteristic &1 at material &2 has unusable field name: &3
What causes this issue? In the configuration model, a reference characteristic exists with reference to a field which is not supported in any integra...
PMEVC_UI404
Reference characteristic &1 at material &2 has unusable table name: &3
What causes this issue? In the configuration model, a reference characteristic exists with reference to a table or structure which is not supported i...
PMEVC_UI407
No knowledge base exists
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
PMEVC_UI408
Knowledge base &1 does not have runtime versions
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.