Do you have any question about this error?
Message type: E = Error
Message class: /PLMI/RCA_EXPL -
Message number: 019
Message text: Recipe &1 not exploded; it is not marked as relevant for explosion
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/PLMI/RCA_EXPL019
- Recipe &1 not exploded; it is not marked as relevant for explosion ?The SAP error message
/PLMI/RCA_EXPL019 Recipe &1 not exploded; it is not marked as relevant for explosion
typically occurs in the context of SAP's Recipe Management or Process Industries modules. This error indicates that the specified recipe (identified by&1
) is not set up to be exploded, meaning that the system does not consider it relevant for the explosion process.Cause:
- Recipe Configuration: The recipe in question is not marked as relevant for explosion in its configuration settings. This could be due to the recipe being incomplete or not intended for use in production.
- Status of the Recipe: The recipe may be in a status that does not allow it to be exploded (e.g., it might be in a draft or inactive state).
- Missing Parameters: Required parameters or settings for the recipe explosion might be missing or incorrectly configured.
Solution:
Check Recipe Settings:
- Go to the recipe in question and check its configuration.
- Ensure that the recipe is marked as relevant for explosion. This can usually be found in the recipe's general settings or attributes.
Review Recipe Status:
- Ensure that the recipe is in an active status. If it is in a draft or inactive state, change it to active.
Validate Parameters:
- Check if all necessary parameters for the recipe explosion are filled out correctly. This includes checking for any missing components or settings that are required for the explosion process.
Consult Documentation:
- Refer to SAP documentation or help resources for specific details on how to configure recipes for explosion. This can provide insights into any additional settings that may be required.
Testing:
- After making the necessary changes, attempt to explode the recipe again to see if the issue is resolved.
Related Information:
C201
(Create Recipe) or C202
(Change Recipe), to access and modify the recipe settings.If the issue persists after following these steps, it may be beneficial to consult with your SAP support team or a functional consultant who specializes in Recipe Management or Process Industries.
Get instant SAP help. Start your 7-day free trial now.
/PLMI/RCA_EXPL018
Technical error; contact your system administrator
What causes this issue? The graph cannot be updated due to missing outputs.System Response The system cannot perform the explosion.How to fix this e...
/PLMI/RCA_EXPL016
Recipe &1 not exploded; recipe purpose is not in sequence of start recipe
What causes this issue? The recipe pupose is not defined in the sequence of the recipe purpose of the start recipe.System Response The system does n...
/PLMI/RCA_EXPL020
Recipe &1 not exploded; it is not the last recipe that was released
What causes this issue? The recipe is not the latest one to be released. Since the filter criteria for the explosion that were implemented in the Bus...
/PLMI/RCA_EXPL021
Recipe &1 not exploded; it is not the last recipe that was created
What causes this issue? A recipe exists which is newer than recipe &V1&. The system issues an error message and will not allow you to continu...
Click on this link to search all SAP messages.