Do you have any question about this error?
Message type: E = Error
Message class: /PLMI/PPECMP -
Message number: 332
Message text: &1 &2 not an assembly group for an assembly
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/PLMI/PPECMP332
- &1 &2 not an assembly group for an assembly ?The SAP error message
/PLMI/PPECMP332 &1 &2 not an assembly group for an assembly
typically occurs in the context of Production Planning and Control (PP) or Logistics Execution (LE) when there is an issue related to assembly groups in the system. This error indicates that the specified assembly group does not match the assembly being processed.Cause:
Incorrect Assembly Group Assignment: The assembly group specified in the transaction does not correspond to the assembly being referenced. This could happen if the assembly group is not correctly defined in the material master or if the assembly is not assigned to the correct group.
Missing Configuration: The assembly group may not be configured properly in the system, or the assembly itself may not be set up to belong to any assembly group.
Data Inconsistency: There may be inconsistencies in the data related to the assembly or the assembly group, such as missing entries in the relevant tables.
Solution:
Check Assembly Group Configuration:
- Go to the material master (transaction
MM03
) and check the assembly group assigned to the material.- Ensure that the assembly group is correctly defined and that the assembly is assigned to the correct group.
Verify Assembly Group Settings:
- Use transaction
SPRO
to navigate to the relevant configuration settings for assembly groups and ensure that they are set up correctly.Review Material Master Data:
- Ensure that the material master data for the assembly is complete and accurate. Check for any missing or incorrect entries.
Check for Data Consistency:
- Run consistency checks or reports to identify any discrepancies in the data related to the assembly and assembly group.
Consult Documentation:
- Review SAP documentation or notes related to this error message for any specific guidance or patches that may address the issue.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to SAP support for further assistance, providing them with the error message details and any relevant transaction codes.
Related Information:
MM03
(Display Material), CS03
(Display Material BOM), and SPRO
(Customizing).By following these steps, you should be able to identify the cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
/PLMI/PPECMP322
Class entry for &1 &2 not allowed
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/PLMI/PPECMP320
Fixed quantity in change status &1 of &2 &3 not allowed in header data
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/PLMI/PPECMP350
&1 &2 already exists in assembly header &3
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
/PLMI/PPECMP351
&1 &2 of &3 &4 still used in header data
What causes this issue? You want to delete an object but the header data for the product structure exists for this object.System Response This syste...
Click on this link to search all SAP messages.