Message type: E = Error
Message class: /PLMI/BO_RFO -
Message number: 003
Message text: Output stream cannot be assigned to &1 &2
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
/PLMI/BO_RFO003
- Output stream cannot be assigned to &1 &2 ?The SAP error message /PLMI/BO_RFO003 Output stream cannot be assigned to &1 &2 typically occurs in the context of Business Object (BO) reporting or output management within SAP systems. This error indicates that there is an issue with the assignment of an output stream to a specific object or process. Causes: Incorrect Output Configuration: The output stream may not be properly configured in the system, leading to an inability to assign it to the specified object. Missing Output Type: The output type required for the operation may not be defined or may be missing in the system. Authorization Issues: The user may not have the necessary authorizations to access or assign the output stream. System
Configuration Issues: There may be issues with the configuration of the output management settings in the SAP system. Data Inconsistencies: There could be inconsistencies in the data that prevent the output stream from being assigned correctly. Solutions: Check Output Configuration: Verify the output configuration
Get instant SAP help. Sign up for our Free Essentials Plan.
/PLMI/BO_RFO002
Specification of formula item &1 not considered for calculation results
What causes this issue? You have assigned a specification to formula item &V1&. For the component type of this item, the explosion does not s...
/PLMI/BO_RFO001
Specification type &1 is not allowed for formula item type of item &2
What causes this issue? You wanted to assign a specification to a formula item, but the specification type of this specification is not allowed for t...
/PLMI/BO_RFO004
Primary output cannot be assigned to &1 &2
What causes this issue? There is an output stream assigned to &V1& &V2&.System Response The system does not change the assignment of...
/PLMI/BO_RFO005
Specifications assigned to streams are not copied into the new recipe
What causes this issue? You have copied a recipe that contains streams with assigned specifications. Specifications for streams can only be used with...
Click on this link to search all SAP messages.