Message type: E = Error
Message class: PK - Production - KANBAN
Message number: 375
Message text: Supply area stor.loc.does not match corresponding entry in WM Customizing
The production supply area is assigned to the storage location &V4&. You
want to use a Kanban to transfer the material in Warehouse Management
(WM) to warehouse number &V2&, storage type &V3&. However, according to
the setting in table T320A in Customizing for Warehouse Management, the
material from warehouse number &V2& and storage type &V3& is assigned to
the storage location &V1&.
In accordance with the above settings, the material is posted to storage
location &V1& and not to the supply area storage location &V4& in
transfer postings in Warehouse Management (WM) or in a physical
inventory.
You have the following options:
Assign another storage location to the supply area.
Enter another storage type in the control circle.
In Customizing for Warehouse Management, in the process step
<DS:SIMG.SIMG_XXMENUOLML1003>Define Storage Location Control</> under
<LS>Storage Location Control in Warehouse Management</>, assign another
storage location to warehouse number &V2& and storage type &V3& in the
relevant plant.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
PK375
- Supply area stor.loc.does not match corresponding entry in WM Customizing ?The SAP error message PK375, which states "Supply area stor.loc. does not match corresponding entry in WM Customizing," typically occurs in the context of Warehouse Management (WM) when there is a mismatch between the storage location defined in the supply area and the configuration in the WM customizing settings.
Cause: Mismatch in Configuration: The storage location defined in the supply area does not match the storage location settings in the Warehouse Management customizing. This can happen if the storage location was changed or if the supply area was incorrectly defined. Incorrect Supply Area Assignment: The supply area may not be correctly assigned to the storage location in the WM settings. Data Inconsistency: There may be inconsistencies in the master data or configuration settings that lead to this error.
Solution: To resolve the PK375 error, you can follow these steps: Check Supply Area Configuration: Go to the transaction code SPRO to access the SAP Customizing Implementation Guide. Navigate to Logistics
Get instant SAP help. Sign up for our Free Essentials Plan.
PK374
Supply area used in control cycles; storage location change not possible
What causes this issue? You have assigned another storage location to the production supply area. However, this production supply area is used in con...
PK373
Default value(s) taken from Kanban Customizing
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
PK376
No inventory document found for the selection criteria
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...