How To Fix PIC01612 - & PICPS-entries created


SAP Error Message - Details

  • Message type: E = Error

  • Message class: PIC01 - Parts Interchangeability Message Class

  • Message number: 612

  • Message text: & PICPS-entries created

  • Show details Hide details


  • Self-Explanatory Message

    Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.

    To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.

    Unfortunately, there isn't any extra information in this error notice.



    What else can you do?

    First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).

    Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.

    You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.


Smart SAP Assistant

  • What is the cause and solution for SAP error message PIC01612 - & PICPS-entries created ?

    The SAP error message PIC01612 typically relates to issues with the creation of PICPS (Production Information Center - Production Scheduling) entries. This error can occur in various contexts, often linked to production planning and scheduling processes.

    Cause of Error PIC01612

    The error message PIC01612 usually indicates that there is a problem with the data or configuration related to the production scheduling process. Common causes include:

    1. Missing or Incorrect Data: Required data for creating PICPS entries may be missing or incorrectly configured. This can include master data like material master, routing, or work center information.

    2. Configuration Issues: There may be issues with the configuration settings in the production planning module, such as settings related to production versions or planning strategies.

    3. Authorization Issues: The user may not have the necessary authorizations to create or modify PICPS entries.

    4. System Errors: There could be underlying system errors or inconsistencies in the database that prevent the creation of entries.

    Solution

    To resolve the PIC01612 error, you can follow these steps:

    1. Check Master Data: Ensure that all relevant master data (material, routing, work centers) is correctly maintained and complete. Verify that the necessary data is available for the production order or scheduling process.

    2. Review Configuration: Check the configuration settings in the production planning module. Ensure that the production versions, planning strategies, and other relevant settings are correctly defined.

    3. Authorization Check: Verify that the user has the necessary authorizations to create or modify PICPS entries. If not, consult with your SAP security team to grant the required permissions.

    4. Analyze Logs: Check the system logs for any additional error messages or warnings that may provide more context about the issue. Use transaction codes like SLG1 (Application Log) to review logs.

    5. Consult Documentation: Refer to SAP documentation or notes related to the specific error message for additional troubleshooting steps or known issues.

    6. Contact SAP Support: If the issue persists after checking the above points, consider reaching out to SAP support for further assistance. Provide them with detailed information about the error, including any relevant logs or screenshots.

    Related Information

    • Transaction Codes: Familiarize yourself with relevant transaction codes such as CO01 (Create Production Order), CO02 (Change Production Order), and CO03 (Display Production Order) to manage production orders effectively.
    • SAP Notes: Search for SAP Notes related to PIC01612 in the SAP Support Portal for any patches or updates that may address the issue.
    • User Forums: Engage with SAP community forums or user groups where similar issues may have been discussed, and solutions shared.

    By following these steps, you should be able to identify and resolve the underlying cause of the PIC01612 error in SAP.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
ERPlingo's SAP support assistant is amazing. Saves me countless hours trying to solve complex SAP issues myself. It's a real game changer!
Rate 1
Thomas Michael
SAP Consultant, Author & Speaker