Do you have any question about this error?
Message type: E = Error
Message class: OQ_C - IS-Oil SSR : Message pool Fuels
Message number: 601
Message text: More than one entry selected as main MM process for location indicator &1
You have not made the necessary entries.
This combination is not permitted.
Make sure that the entries are correct. Each location should have
exactly one process that is selected as a main process.
Error message extract from SAP system. Copyright SAP SE.
OQ_C601
- More than one entry selected as main MM process for location indicator &1 ?The SAP error message OQ_C601 indicates that there is an issue with the configuration of the Material Management (MM) process for a specific location indicator. This error typically arises when the system finds multiple entries that are marked as the main process for a given location indicator, which leads to ambiguity in processing.
Cause:
The primary cause of this error is that there are multiple entries in the configuration that are set as the main MM process for the same location indicator. This can happen due to:
- Duplicate Entries: There may be duplicate entries in the configuration tables for the location indicator.
- Incorrect Configuration: The configuration settings for the MM process may not have been set up correctly, leading to multiple main processes being defined.
- Data Migration Issues: If data was migrated from another system, it may have resulted in duplicate or conflicting entries.
Solution:
To resolve the OQ_C601 error, you can follow these steps:
Check Configuration:
- Go to the configuration settings for the MM process related to the location indicator in question.
- Use transaction codes like
SPRO
to access the configuration menu.- Navigate to the relevant section for defining the MM process and check for multiple entries for the same location indicator.
Identify Duplicates:
- Use transaction codes like
SE16
orSE11
to view the relevant database tables (e.g., T001W for plant data) and identify any duplicate entries for the location indicator.Correct the Entries:
- If duplicates are found, determine which entry should be the main process and delete or deactivate the others.
- Ensure that only one entry is marked as the main MM process for the location indicator.
Testing:
- After making the necessary changes, test the configuration to ensure that the error no longer occurs.
- Perform transactions that previously triggered the error to confirm that the issue is resolved.
Documentation:
- Document the changes made to the configuration for future reference and to prevent similar issues from occurring.
Related Information:
SPRO
, SE16
, SE11
, and MM01
for material master data.By following these steps, you should be able to resolve the OQ_C601 error and ensure that your MM process configuration is set up correctly for the specified location indicator.
Get instant SAP help. Start your 7-day free trial now.
OQ_C600
Only display possible. Maintenance via location master record
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OQ_C599
********************* Material movements*********************************
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OQ_C602
No entry is selected as a main MM process for location indicator &1
What causes this issue? You have not made the required entries.System Response The combination of data that you entered is not allowed.How to fix th...
OQ_C603
No logistics document schema assigned to location indicator &1,process &2
What causes this issue? You tried to execute process &V2& creating a logistic document (e.g. a material movement document) for business locat...
Click on this link to search all SAP messages.