Do you have any question about this error?
Message type: E = Error
Message class: OQ_C - IS-Oil SSR : Message pool Fuels
Message number: 362
Message text: Meter reading created for mat./s.t/eq. &1/&2/&3, sequence number &4.
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
OQ_C362
- Meter reading created for mat./s.t/eq. &1/&2/&3, sequence number &4. ?The SAP error message OQ_C362 indicates that a meter reading has been created for a material, service type, or equipment, and it is associated with a specific sequence number. This message typically arises in the context of SAP's Plant Maintenance (PM) or Customer Service (CS) modules, where meter readings are used to track usage or consumption of resources.
Cause:
The error message OQ_C362 can occur due to several reasons:
- Duplicate Meter Reading: The system may be trying to create a meter reading that already exists for the specified material, service type, or equipment with the same sequence number.
- Incorrect Sequence Number: The sequence number provided may not match the expected sequence for the meter readings, leading to inconsistencies.
- Configuration Issues: There may be configuration settings in the system that are not aligned with the expected behavior for meter readings.
- Data Integrity Issues: There could be issues with the underlying data, such as missing or incorrect entries in the relevant tables.
Solution:
To resolve the OQ_C362 error, you can take the following steps:
Check for Existing Meter Readings:
- Verify if a meter reading already exists for the specified material, service type, or equipment with the same sequence number. You can do this by checking the relevant transaction codes (e.g., IW39 for PM orders, or the appropriate transaction for service orders).
Review Sequence Number:
- Ensure that the sequence number you are trying to use is correct and follows the expected sequence. If necessary, adjust the sequence number to avoid duplication.
Correct Configuration:
- Review the configuration settings related to meter readings in the SAP system. Ensure that they are set up correctly according to your business processes.
Data Validation:
- Perform a data validation check to ensure that all relevant entries in the database are correct and complete. Look for any inconsistencies or missing data that could be causing the issue.
Consult Documentation:
- Refer to SAP documentation or help resources for additional context on the error message and its implications.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to SAP support for further assistance. They may provide insights specific to your system configuration and usage.
Related Information:
By following these steps, you should be able to identify the cause of the OQ_C362 error and implement a suitable solution.
Get instant SAP help. Start your 7-day free trial now.
OQ_C361
Meter readings already processed with &1 &2
What causes this issue? Some of the last set of meter readings have already been processed with the &V1& &V2&. They are no longer off...
OQ_C360
The counter entered (&1) has more digits than allowed (&2)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OQ_C363
Meter reading created for material &1, service type &2, seq. no. &3.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OQ_C364
Meter reading created for material &1, sequence number &2.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.