Do you have any question about this error?
Message type: E = Error
Message class: OIURR - Production Regulatory Reporting
Message number: 059
Message text: Injectionn pressure QCI conversion error: WL/WC &, Daily Pressure UoM &
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
OIURR059
- Injectionn pressure QCI conversion error: WL/WC &, Daily Pressure UoM & ?The SAP error message OIURR059, which indicates an "Injection pressure QCI conversion error," typically arises in the context of the SAP Oil and Gas (SAP OIL) module, particularly when dealing with injection pressure data in the context of well operations.
Cause:
The error message suggests that there is an issue with the conversion of the injection pressure from one unit of measurement (UoM) to another. This can occur due to several reasons:
Incorrect Unit of Measurement Configuration: The system may not be able to find the correct conversion factors for the specified units of measurement (WL/WC, Daily Pressure UoM).
Missing or Incomplete Data: The required data for the conversion might be missing or incorrectly entered in the system.
Data Type Mismatch: The data being processed may not match the expected format or type, leading to conversion errors.
Configuration Issues: There may be issues in the configuration settings related to the measurement units in the SAP system.
Solution:
To resolve the OIURR059 error, you can take the following steps:
Check Unit of Measurement Configuration:
- Go to the configuration settings in SAP and verify that the units of measurement for injection pressure are correctly defined.
- Ensure that the conversion factors between the units are properly set up.
Validate Input Data:
- Review the data being input for injection pressure to ensure that it is complete and correctly formatted.
- Check for any missing values or incorrect entries that could lead to conversion issues.
Review Master Data:
- Ensure that the master data related to the wells and injection points is accurate and up-to-date.
- Check if the relevant characteristics for the wells are correctly defined.
Consult Documentation:
- Refer to SAP documentation or help resources for specific guidance on handling unit conversion errors in the Oil and Gas module.
Debugging:
- If you have access to debugging tools, you can trace the process to identify where the conversion is failing.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to SAP support for further assistance.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the OIURR059 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
OIURR058
Well completion daily pressures (inje psi) not found: WL/WC &, From dt &
What causes this issue? Injection Pressure is taken from Well Completions Daily Pressures table, oiurp_wcdps. A record was not found for the Well Co...
OIURR057
& & not in application data common table; well completion &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIURR060
No pperator can be maintained as no finalization Level is defined for &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIURR061
TrnspOGRID not found: Trnsp &, OrigMP &, WC &, VT &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.