How To Fix OIUPR874 - A well test was not found for WL/WC & & in the last 24 months.


SAP Error Message - Details

  • Message type: E = Error

  • Message class: OIUPR - PRA Production Messages

  • Message number: 874

  • Message text: A well test was not found for WL/WC & & in the last 24 months.

  • Show details Hide details


  • Self-Explanatory Message

    Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.

    To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.

    Unfortunately, there isn't any extra information in this error notice.



    What else can you do?

    First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).

    Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.

    You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.


Smart SAP Assistant

  • What is the cause and solution for SAP error message OIUPR874 - A well test was not found for WL/WC & & in the last 24 months. ?

    The SAP error message OIUPR874 indicates that a well test was not found for a specific Well Location (WL) or Well Completion (WC) in the last 24 months. This error typically arises in the context of oil and gas operations, particularly when dealing with well performance data and testing records.

    Cause:

    1. Missing Well Test Data: The primary cause of this error is the absence of well test data for the specified well location or completion within the last 24 months. This could be due to:

      • No tests being conducted during that period.
      • Data not being entered or recorded in the SAP system.
      • Data being archived or deleted.
    2. Incorrect Well Location or Completion: The error may also occur if the specified well location or completion identifier is incorrect or does not exist in the system.

    3. Data Synchronization Issues: If there are issues with data synchronization between different systems or modules, it may lead to the absence of expected well test records.

    Solution:

    1. Verify Well Test Records: Check the well test records for the specified well location or completion in the SAP system. Ensure that tests have been conducted and recorded within the last 24 months.

    2. Data Entry: If tests were conducted but not recorded, ensure that the data is entered into the system. This may involve:

      • Manually entering the test data.
      • Importing data from external sources if applicable.
    3. Check Well Identifier: Confirm that the well location or completion identifier used in the transaction is correct. If there is a typo or incorrect reference, correct it and try again.

    4. Consult with Data Management Team: If you suspect that data may have been archived or deleted, consult with your data management or IT team to retrieve the necessary records.

    5. Review System Configuration: Ensure that the SAP system is configured correctly to capture and report well test data. This may involve checking settings related to well test management.

    6. Run Reports: Use SAP reporting tools to generate reports on well tests to identify any gaps in data for the specified well.

    Related Information:

    • SAP Modules: This error is typically related to the SAP Oil & Gas (SAP O&G) module, particularly in the context of Production and Well Management.
    • Documentation: Refer to SAP documentation or user manuals specific to well test management for detailed procedures on data entry and reporting.
    • User Training: Ensure that users involved in data entry and management are adequately trained on the importance of maintaining accurate well test records.

    By following these steps, you should be able to resolve the OIUPR874 error and ensure that well test data is accurately recorded and maintained in the SAP system.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
ERPlingo's SAP support assistant is amazing. Saves me countless hours trying to solve complex SAP issues myself. It's a real game changer!
Rate 1
Thomas Michael
SAP Consultant, Author & Speaker