Do you have any question about this error?
Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 720
Message text: Unable to locate MP profile with vli = vol calc from FS
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
OIUPR720
- Unable to locate MP profile with vli = vol calc from FS ?The SAP error message OIUPR720, which states "Unable to locate MP profile with vli = vol calc from FS," typically occurs in the context of SAP's Oil and Gas or Utilities modules, particularly when dealing with volume calculations and master profiles.
Cause:
This error generally indicates that the system is unable to find a matching Master Profile (MP) for the specified volume calculation (vli) in the system. This can happen due to several reasons:
- Missing Master Profile: The required Master Profile for the volume calculation may not be defined in the system.
- Incorrect Configuration: There may be a configuration issue where the volume calculation is not correctly linked to the Master Profile.
- Data Inconsistency: There could be inconsistencies in the data that prevent the system from locating the appropriate profile.
- Authorization Issues: Sometimes, the user may not have the necessary authorizations to access the Master Profile.
Solution:
To resolve the OIUPR720 error, you can take the following steps:
Check Master Profiles:
- Navigate to the relevant configuration settings in SAP and verify that the Master Profile for the volume calculation is defined.
- Ensure that the profile is active and correctly configured.
Review Volume Calculation Settings:
- Check the settings related to volume calculations to ensure they are correctly linked to the Master Profile.
- Make sure that the volume calculation type is correctly set up in the system.
Data Consistency Check:
- Perform a data consistency check to identify any discrepancies in the configuration or master data that may be causing the issue.
Authorization Check:
- Ensure that the user encountering the error has the necessary authorizations to access the Master Profile and perform the required operations.
Consult Documentation:
- Refer to SAP documentation or notes related to the specific module you are working with for any additional troubleshooting steps or known issues.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to SAP support for further assistance. Provide them with the error message details and any relevant configuration information.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the OIUPR720 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
OIUPR719
Fuel System adj metered qy < allocating vol, so DN is out of balance
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR718
Unable to alloc calculated water chain volume to upstream well/wc's
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR721
Total disposition at the MP was not allocated to all upstream nodes
What causes this issue? While processing the fuel system, the total disposition at the listed MP was not allocated to all nodes upstream. The quanti...
OIUPR722
A DEFAULT TRANSPORTER WAS NOT FOUND FOR THE LISTED MP
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.