Do you have any question about this error?
Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 607
Message text: FATAL: CHEM ANALYSIS CONTAINED NON-ZERO MOL % OR VOL % FOR A COMPONENT
THE COMPONENT FORMS AN INVALID MATERIAL CODE FOR THE VOLUME THAT IS
BEING CALCULATED
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
OIUPR607
- FATAL: CHEM ANALYSIS CONTAINED NON-ZERO MOL % OR VOL % FOR A COMPONENT ?The SAP error message OIUPR607 indicates that there is an issue with the chemical analysis data for a component in a process or material. Specifically, it suggests that the chemical analysis contains non-zero mole percentage (mol %) or volume percentage (vol %) for a component that is not expected to have a value in that context. This can occur in various scenarios, such as when dealing with materials that have specific composition requirements.
Cause:
- Incorrect Data Entry: The most common cause is that the chemical analysis data has been entered incorrectly, leading to non-zero values for components that should not have them.
- Configuration Issues: There may be configuration issues in the material master or the relevant process that do not align with the expected chemical composition.
- Missing or Incorrect Component Definitions: The components defined in the system may not match the expected components for the chemical analysis, leading to discrepancies.
- Validation Rules: The system may have validation rules that are not being met due to the presence of unexpected values.
Solution:
- Review Chemical Analysis Data: Check the chemical analysis data for the material or process in question. Ensure that all components have the correct values, particularly those that should be zero.
- Correct Data Entry: If incorrect values are found, correct them in the relevant transaction or master data record.
- Check Material Master: Review the material master data to ensure that the components and their expected values are correctly defined.
- Consult Configuration Settings: If the issue persists, consult with your SAP configuration team to review the settings related to chemical analysis and ensure they are set up correctly.
- Run Validation Checks: If applicable, run any validation checks or reports to identify other potential issues with the chemical analysis data.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the OIUPR607 error message in SAP.
Get instant SAP help. Start your 7-day free trial now.
OIUPR606
FATAL: VOL WAS FND AT THE MP THAT IS INVALID, BASED ON THE CHEM ANALYSIS
What causes this issue? A VOLUME WAS FOUND AT THE MP THAT IS INVALID, BASED ON THE CHEMICAL ANALYSIS. EITHER A GAS VOLUME WAS FOUND FOR A LIQUID CHE...
OIUPR605
FATAL: TYPIFICATION LVL OF CHEM ANALYSIS ISN'T COMPAT W/ NTWK COMPAT LVL
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR608
FATAL: THE MP NEEDED A WEIGHTED AVERAGE CHEMICAL ANALYSIS CALCULATED
What causes this issue? THE EXISTING ANALYSIS AT THAT MP ARE NON-CALCULATED. WEIGHTED AVERAGE ANALYSIS CAN ONLY BE CALCULATED CALCULATED.System Res...
OIUPR609
FATAL: AN INVALID COMPONENT VOLUME WAS FOUND WHILE CALCULATING A VOL
What causes this issue? EITHER THE COMPONENT IS INCOMPATIBLE WITH THE NETWORK COMPATIBILITY LEVEL, OR THE COMPONENT IS INVALID FOR THE MATERIAL OF TH...
Click on this link to search all SAP messages.