Do you have any question about this error?
Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 532
Message text: Gas plant DN has more than one furtherst downstream node
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
OIUPR532
- Gas plant DN has more than one furtherst downstream node ?The SAP error message OIUPR532 indicates that there is an issue with the configuration of a gas plant in the SAP system, specifically related to the downstream nodes in the network. This error typically arises in the context of the SAP Oil & Gas module, particularly when dealing with the modeling of gas transportation networks.
Cause:
The error message "Gas plant DN has more than one furthest downstream node" suggests that the gas plant (DN) is configured in such a way that it has multiple nodes that are considered the furthest downstream. In a gas network, each node should have a clear and singular path for gas flow, and having multiple furthest downstream nodes can create ambiguity in the flow calculations and network modeling.
Solution:
To resolve this error, you can take the following steps:
Review the Network Configuration:
- Check the configuration of the gas plant and its associated nodes in the SAP system.
- Ensure that each gas plant has a single furthest downstream node. This may involve reviewing the connections and relationships between the gas plant and its downstream nodes.
Adjust Node Relationships:
- If there are multiple nodes that are incorrectly set as the furthest downstream, you will need to determine which node should be designated as the furthest downstream.
- Update the configuration to reflect this change, ensuring that only one node is marked as the furthest downstream.
Validate Data Integrity:
- After making changes, validate the data integrity of the network model to ensure that there are no other inconsistencies or errors.
- Run any necessary checks or simulations to confirm that the network operates correctly with the updated configuration.
Consult Documentation:
- Refer to SAP documentation or user manuals specific to the Oil & Gas module for additional guidance on configuring gas plants and nodes.
- If needed, consult with SAP support or a specialist who has experience with the Oil & Gas module for further assistance.
Related Information:
By following these steps, you should be able to resolve the OIUPR532 error and ensure that your gas plant configuration is correct.
Get instant SAP help. Start your 7-day free trial now.
OIUPR531
Indicated material is inconsistent with the well class for the wc
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR530
A gas plant inlet was found in a DN that is not a Gas Plant
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR533
Node is in an 'N', 'W', OR 'M' structure
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR534
Fuel system has a produced or purchased fuel point as FUN
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.