Do you have any question about this error?
Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 516
Message text: DN & does not have a Furthest Downstream Node
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
OIUPR516
- DN & does not have a Furthest Downstream Node ?The SAP error message OIUPR516 indicates that a Downstream Node (DN) does not have a Furthest Downstream Node associated with it. This error typically occurs in the context of SAP's Oil and Gas or Utilities modules, particularly when dealing with the management of pipeline networks or similar structures.
Cause:
- Missing Configuration: The error often arises when the system is unable to find a valid furthest downstream node for a given downstream node. This could be due to missing or incorrect configuration in the pipeline or network setup.
- Data Integrity Issues: There may be issues with the data integrity in the master data records, such as missing relationships between nodes.
- Incorrect Node Setup: The downstream node may not be properly defined or linked to other nodes in the system.
Solution:
- Check Node Configuration: Review the configuration of the downstream node in question. Ensure that it is correctly set up and linked to the appropriate furthest downstream node.
- Data Validation: Validate the master data for the nodes involved. Ensure that all necessary relationships and attributes are correctly defined.
- Update Relationships: If the furthest downstream node is missing, you may need to create or update the relationship in the system to establish the correct hierarchy.
- Consult Documentation: Refer to SAP documentation or help resources specific to your version of the software for detailed instructions on how to manage nodes and their relationships.
- System Check: If the issue persists, consider running a system check or data consistency check to identify any other underlying issues that may be causing the error.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the OIUPR516 error message in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
OIUPR515
MST MP & has no upstream node connections
What causes this issue? The volume indicator on the MPAP of the listed MP indicates that the MP volume will be computed from well completion downtime...
OIUPR514
More than one tank battery exists in the DN structure
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR517
DN & has more than one Furthest Downstream Node
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR518
A MP Allocation Profile was not found for listed material and volume type
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.