Do you have any question about this error?
Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 380
Message text: DN Alloc Seq 0 is not allowed with TCM = SW (Single WellCompletion )
Sequence 0 in the Delivery Network Allocation Profile is not allowed
when the Theoretical Calculation Method for that major product is 'SW'
Single Well Completion.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
OIUPR380
- DN Alloc Seq 0 is not allowed with TCM = SW (Single WellCompletion ) ?The SAP error message OIUPR380 indicates that there is an issue with the allocation sequence in the context of a single well completion (SW) in the SAP system, particularly in the Oil and Gas industry module (often referred to as SAP IS-Oil). This error typically arises when there is a mismatch or an incorrect configuration related to the allocation sequence and the transaction control method (TCM).
Cause:
- Incorrect Allocation Sequence: The allocation sequence specified (in this case, 0) is not valid for the transaction control method (SW) being used. This could be due to a configuration issue where the allocation sequence is not set up correctly for single well completions.
- Configuration Issues: The system may not be configured to handle the allocation sequence for the specific well completion type you are working with.
- Data Entry Errors: There may be errors in the data entry where the allocation sequence is incorrectly specified or not applicable for the given context.
Solution:
Check Allocation Sequence Configuration:
- Navigate to the configuration settings for allocation sequences in your SAP system.
- Ensure that the allocation sequence for single well completions is correctly defined and that it allows for the specified sequence (in this case, 0).
Review Transaction Control Method:
- Verify that the transaction control method (TCM) is set correctly for the well completion you are working with. If it is set to SW, ensure that the allocation sequence is compatible with this method.
Correct Data Entry:
- Review the data entry for the allocation sequence. Ensure that the correct sequence number is being used and that it aligns with the expected values for the TCM.
Consult Documentation:
- Refer to SAP documentation or help resources specific to the IS-Oil module for guidance on allocation sequences and transaction control methods.
Contact SAP Support:
- If the issue persists after checking the configuration and data entry, consider reaching out to SAP support for further assistance. They may provide insights specific to your system configuration and version.
Related Information:
By following these steps, you should be able to identify the cause of the OIUPR380 error and implement the necessary solutions to resolve it.
Get instant SAP help. Start your 7-day free trial now.
OIUPR379
WL: & WC : & is upstream of more than one RLF MP
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR365
Load Oil w/o Recovery flag can only be selected for L1 volume types.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR399
Please enter API WC NO in format "Char Num Num" only.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR400
Report must be closed for production date.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.