Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 251
Message text: This is not a valid Major Product/Ratio Code combination.
Major product code/Ratio code must be one of the following valid
combinations: Natural Gas/Gas Lift to Gas Ratio or Gas Liquid Ratio or
Gas Oil Ratio, Water/Water Gas Ratio or Water Oil Ratio, Oil/Oil Gas
Ratio, and Condensate/Oil Gas Ratio.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
OIUPR251
- This is not a valid Major Product/Ratio Code combination. ?The SAP error message OIUPR251, which states "This is not a valid Major Product/Ratio Code combination," typically occurs in the context of SAP's Oil and Gas industry solutions, particularly when dealing with product pricing, inventory management, or related transactions.
Cause: This error usually arises due to one of the following reasons: Invalid Major Product Code: The Major Product Code entered does not exist in the system or is not correctly defined in the master data. Invalid Ratio Code: The Ratio Code associated with the Major Product is either missing or does not match the expected combinations defined in the system.
Configuration Issues: There may be configuration issues in the system where the Major Product and Ratio Code combinations are not properly set up. Data Entry Errors: There could be typographical errors or incorrect data entry when inputting the Major Product or Ratio Code.
Solution: To resolve the OIUPR251 error, you can take the following steps: Check Major Product Code: Verify
Get instant SAP help. Sign up for our Free Essentials Plan.
OIUPR250
Major Product Code & is required when Ratio Code is &.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR249
This record cannot be created. Please see long text.
What causes this issue? The system issues an error message and will not allow you to continue with this transaction until the error is resolved. Syst...
OIUPR252
Configuration does not allow a Plant DN TCM record to be inserted.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR253
Please select a Unit of Measure without conditions.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.