Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 171
Message text: & & & & must exist on Measurement Point Transporter Cross reference table
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
OIUPR171
- & & & & must exist on Measurement Point Transporter Cross reference table ?The SAP error message OIUPR171 indicates that a specific entry is missing in the Measurement Point Transporter Cross Reference table. This error typically arises in the context of SAP IS-U (Industry Solution for Utilities) when dealing with measurement points and their associated transporters.
Cause: The error occurs when the system is trying to access or process a measurement point that does not have a corresponding entry in the Measurement Point Transporter Cross Reference table (usually referred to as the "Measurement Point Transporter" or "Transporter Cross Reference" table). This can happen due to: Missing Data: The required entry for the measurement point and transporter has not been created in the system. Data Migration Issues: If data was migrated from another system, some entries may not have been transferred correctly.
Configuration Issues: The configuration settings for measurement points or transporters may not be set up correctly.
Solution: To resolve the OIUPR171 error, you can take the following steps: Check the
Get instant SAP help. Sign up for our Free Essentials Plan.
OIUPR170
Measurement Point required when Transporter & Transporter ref not entered
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR169
Well Class & requires an & material.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR172
Typ lvl, basis, type, and calc must be blank when Source MP specified.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR173
Volume Type must be Measured Production or Allocation Volume
What causes this issue? If MP Type is Allocation Meter or Production Meter and Volume Indicator is required or optional, then Volume Type must be Me...
Click on this link to search all SAP messages.