Do you have any question about this error?
Message type: E = Error
Message class: OIUPR - PRA Production Messages
Message number: 082
Message text: No fields to be transferred to MP volumes record
The measurement system will usually transfer one or more readings from
the measurement into the measurement point volumes document. These are
the standard readings that will be used in subsequent processing such
as volumes allocations and contractual allocations.
In this case the configuration of the measurement point volumes
indicates that there are no readings to be transferred.
It may be valid that there are no readings to be transferred, but it is
such an unusual case that a warning is issued.
Confirm that no standard readings are to be transferred to the
measurement point volumes document.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
OIUPR082
- No fields to be transferred to MP volumes record ?The SAP error message OIUPR082, which states "No fields to be transferred to MP volumes record," typically occurs in the context of the SAP Oil and Gas module, particularly when dealing with the management of volumes in the context of production or inventory management.
Cause:
This error usually arises when the system attempts to create or update a record in the MP (Measurement Point) volumes table, but there are no valid fields or data available to be transferred. This can happen due to several reasons, including:
- Missing Data: Required fields for the volume record are not populated. This could be due to missing measurement data or incomplete entries in the relevant master data.
- Configuration Issues: The configuration settings for the measurement points or volume records may not be set up correctly, leading to a lack of data being available for transfer.
- Data Consistency: There may be inconsistencies in the data that prevent the system from identifying valid fields to transfer.
- User Authorization: The user may not have the necessary permissions to access or modify the relevant data.
Solution:
To resolve the OIUPR082 error, you can take the following steps:
- Check Data Entry: Ensure that all required fields for the measurement point and volume records are filled out correctly. Verify that the measurement data is complete and accurate.
- Review Configuration: Check the configuration settings for the measurement points and volume records in the SAP system. Ensure that all necessary settings are correctly defined.
- Data Consistency Check: Run consistency checks on the relevant data to identify any discrepancies or missing information that could be causing the issue.
- User Permissions: Verify that the user has the appropriate authorizations to access and modify the relevant data. If necessary, consult with your SAP security team to adjust permissions.
- Consult Documentation: Refer to SAP documentation or notes related to the Oil and Gas module for any specific guidance on handling this error.
- Debugging: If the issue persists, consider using debugging tools to trace the process and identify where the data transfer is failing.
Related Information:
By following these steps, you should be able to identify the root cause of the OIUPR082 error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
OIUPR081
Error found during measurement point volumes posting
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR080
Measurement type & does not exist
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUPR083
Reading & is not available for transfer in measurement type &.
What causes this issue? The measurement system will usually transfer one or more readings from the measurement into the measurement point volumes doc...
OIUPR084
Error transferring field & from measurement type &.
What causes this issue? The measurement system will usually transfer one or more readings from the measurement into the measurement point volumes doc...
Click on this link to search all SAP messages.