Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: OIUME - Measurement messages
Message number: 101
Message text: Maximum Number of Integer Digits (&) has been exceeded on Meter Reading.
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
OIUME101
- Maximum Number of Integer Digits (&) has been exceeded on Meter Reading. ?The SAP error message OIUME101, which states "Maximum Number of Integer Digits (&) has been exceeded on Meter Reading," typically occurs in the context of the SAP IS-U (Industry Solution for Utilities) module when dealing with meter readings. This error indicates that the value being entered for a meter reading exceeds the defined limit for integer digits in the system.
Cause:
- Exceeding Defined Limits: The error is triggered when the meter reading value exceeds the maximum number of integer digits that is configured in the system. This limit is set in the configuration of the meter reading document or the specific meter type.
- Incorrect Meter Configuration: The meter itself may be configured to accept a certain range of values, and if the reading exceeds this range, the error will occur.
- Data Entry Error: There may be a mistake in the data entry process, such as entering an incorrect value or format.
Solution:
Check Configuration:
- Go to the configuration settings for the meter reading in the SAP system. You can check the maximum number of digits allowed for the meter reading.
- Navigate to the relevant configuration path in SPRO:
SAP Customizing Implementation Guide > Cross-Application Components > Utilities > Meter Reading > Define Meter Reading Document
.Adjust Meter Reading Limits:
- If the current limit is too low for the expected meter readings, consider increasing the maximum number of integer digits allowed for the meter reading.
- Ensure that the changes made are in line with the actual capabilities of the meters being used.
Validate Meter Configuration:
- Check the configuration of the specific meter type in the system to ensure it is set up correctly to handle the expected range of readings.
- Ensure that the meter type is correctly linked to the appropriate reading type.
Data Entry Review:
- Review the data entry process to ensure that the values being entered are correct and within the expected range.
- If necessary, provide training or guidelines to users on how to enter meter readings correctly.
Testing:
- After making any changes, conduct tests to ensure that the error no longer occurs and that meter readings can be entered successfully.
Related Information:
By following these steps, you should be able to resolve the OIUME101 error and ensure that meter readings can be processed correctly in your SAP system.
Get instant SAP help. Sign up for our Free Essentials Plan.
OIUME100
Maximum number of decimals (&) has been exceeded for Meter Reading.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUME099
Meas.Type & Rdg.Group & not in work area.
What causes this issue? An internal error has occurred in the Measurement System. More particularly, the current application has requested that meas...
OIUME102
Unknown error occured during meter reading digit determination.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUME103
Meter off reading was less than meter on reading.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.